background image

C:\\HWY_HWYSE112/118EXT

Reinigungssysteme

  ...die sauberste Lösung

Pos.

No.

Bezeichnung

Description

1

ETE504300

Elektromotor 3,0 KW 400V, 50Hz, 1420

Electromotor 3,0 KW, 400V, 50Hz, 1420

2

5680301580

1 Schlauchtülle, 3/8" AG x 13 mm  

brass nipple 3/8" x 13 mm

3

3780000030

2 1/2" Schlauch (Länge angeben)

1/2" hose (order lenght you need)

4

ETE180500

Wassermangelschalter f. Waschbär SE

low water swich

5

5684901208

1 WE-15 x 3/8 Winkelverschraubung,

h.p. fitting

6

ETD500100

Unloaderventil VB 9 m. Druckschalter

unloaderventil VB 9 w. switch

7

5684901060

1 GE 12-PLR-R3/8 Gerade Einschraubvers.

hp fitting

8

ETD161600

1 12 x 3/8" WE RST Sonder - Winkelverschraubung hp fitting

9

5680301500

Schlauchtülle 1/2" AG x 6 mm  

 low pr. Fitting 1/2" AG x 6 mm  

10

5680301350

T-Stück 1/2" Mess. AG x IG x IG

T-pc 1/2" 

11

ETA350040

4 Gummi-Metallpuffer, 40 x 30 mm 2xM8 AG

rubber element

12

ETD345010

1 Verlängerung, 60mm,  1/2" AG x 1/2" IG M

extention brass 1/2" x 60 mm

13

5680301630

1 1/2" Verschraubung,keg. 1/2" Ag.xAG. Mess.

union 1/2" m x m brass

14

5680301410

Winkel 90° 1/2" IG x AG Messing

ellbow 90°  1/2" ma. x fe.

15

3708500518

Hochdruckschlauch 600mm 2ST 10,es AGR 3/8"

hp hose 600mm 2ST 10, es AGR 3/8"

16

3686904003

Muffenschieber 1/2"

sleeve valve

17

5680301490

3 Schlauchtülle,1/2"AG. x 13mm 

brass nipple 1/2" x 13 mm

18

3882800040

Rückwand Waschbär SE montagefertig 

rear panel 

HWY 118EXT_Pumpenaggregat

     

 1

2

     3          4            5

6

7

8

9

18

17

16

                               

15                   14               13                           12             11         10

Summary of Contents for HWY118 EXT

Page 1: ...SPARE PART LIST Waschb r SE 112 118 HWY118 EXT Weidner Reinigungssysteme D 74523 Schw bisch Hall Steinbeisweg 29 Telefon 0791 95012 0 Fax 0791 54 742 e mail info weidner cleaning com Internet www weid...

Page 2: ...Implementing Order oft the Federal Pollution Protection Legislation to ensure that the immission limit values are observed 7 When operatingthe equipmentin rooms a safe discharge ofthe flue gases must...

Page 3: ...in our list of accessories We will be delighted to help you in the choice accessories and cleaning agents suitable for your cleaning needs 14 Befor working on the high pressure cleaner it must be disc...

Page 4: ...his control chain as an accessory If workis interruptedfor longerthan 1 minutes the device should be switched offto saveenergy The device is suitable to remove dirt from surfaces by means of a freely...

Page 5: ...sant hose to the injektor and place the suction filter into the cleansant The quantity of cleansant can be adjusted by turning the hand nut at the cleansant injektor If all the prenamed points are ful...

Page 6: ...m seperate drum turn the gwitch into the direction 2 If the cleangant tank drum is empty the metering valve should be closed pos since otherwise air will be sucked in and the working pressure will dro...

Page 7: ...ean or replace unloader valve leaky or soiled nozzle washed out or replace wrong nozzle size oil leak on crankshaft shaft seal faulty replace seal scheck shaft incrased noise with no loss baring worn...

Page 8: ...Chemical line blocked clean Chemical line faulty replace injector blocked clean injector faulty replace pressure adjustment nozzle too far open closed hp hose too long use a hose w nominal diameter 20...

Page 9: ......

Page 10: ...98 EPACA045891 3 Scheibe disk 99 EPACA104360 3 Plungerhalter plunger owner 100 EPACA0456812 3 Dichtungshalter kmpl seal owner 101 EPACA043302 3 lfilz oil felt 106 EPACA043305 3 ND Dichtung ND seal 12...

Page 11: ...800060 Brennkammer VA Waschb r SE combustion camber 4 ETB220102 Steckdeckel PVC Cover 5 35900001060 Sicherheitsthermostat 95 C mit Tauchh lse safety thermostat with dipping case 6 EPACA00300 Hochdruck...

Page 12: ...ngssysteme die sauberste L sung Pos No Bezeichnung Description 1418 3882800060 Brennkammer VA Waschb r SE combustion chamber 1423 3656040600 Einschraubheizk rper 403K 600 44 3 B G1 6000W heating unit...

Page 13: ...panel 6 ETE504300 Elektromotor 3 0 KW 400V 50Hz 1420 Electromotor 3 0 KW 400V 50Hz 1420 7 ETA200035 Schiebeb gel Waschb r ab 06 19999 handle Version after 06 1999 8 3914900010 Rohrschelle 22 mm Alumi...

Page 14: ...eating 7 ETE186200 Temperaturregler 0 95 C mit Tauchh lse temperature regulator with dipping case 8 ETA200035 Schiebeb gel Waschb r ab 06 19999 handle Version after 06 1999 9 ETA190100 1 Kantenschutz...

Page 15: ...steme die sauberste L sung HWY 118EXT_Schwimmerventil Pos No Bezeichnung Description 1305 3909900153 1 PVC Kunststoffschwimmer 65 x 130 pvc ball 65 x 130 1304 3909900103 1 Schwimmerventil 3 8 12mm 170...

Page 16: ...3 8 WE RST Sonder Winkelverschraubung hp fitting 9 5680301500 Schlaucht lle 1 2 AG x 6 mm low pr Fitting 1 2 AG x 6 mm 10 5680301350 T St ck 1 2 Mess AG x IG x IG T pc 1 2 11 ETA350040 4 Gummi Metall...

Page 17: ...minal block 8 3652251201 Schutzleiterklemme USLKG16N earth terminal 9 3652251110 Reihenklemme UKN16BU terminal block 10 3652251100 Reihenklemme UKN5BU terminal block 11 3652251200 Schutzleiterklemme U...