Fault and remedies
Fault
Possible
cause
Remedy
device does not start
no electricity
check cables, plugs
socket and fuse
thermoprobe motor
deterrnine and remedy
triggered
cause of overload
pilot fuse defect
replace pilot fuse
find out cause if there
is a burn throuh again
pump under pressure
trigger spray gun
water leak
packing worn or plunger pipe defect replace
pump does not reach pressure or
water supply inadequate
open water tap
is loud, pressure fluctations
check float valve
clean water inlet sieve
reduce height of suction
suction valve clogged
rins pump with clear water
soiled or wom valves, packing worn clean or replace
unloader valve leaky or soiled
nozzle washed out or
replace
wrong nozzle size
oil leak on crankshaft
shaft seal faulty
replace seal, scheck shaft
incrased noise with no loss
baring worn out
replace bearing,
of
pressure
change
interval to long
pump oil milky white
condensation water forrnation
reduce oil change
interval
unloader valve tops at short
gun or hp-hose leaky
seal, replace
intervals with gun closed
jack valve or unloader valve worn out replace jach valve
hight pressure gauge defection when
unloader valve incorrectly set or foul adjust unloader valve,
gun
closed
replace
Water volume to small
wrong nozzle size
use nozzle acc. to rating, plates
nozzle dirty
clean or replace
unloader valve too low
set sorrectly
unloader valve faulty
replace
Chemicals are not sucked in
chemical tank emty
fill