Fault and remedies  

Fault 

 

     Possible 

cause 

 

   Remedy 

 

device does not start  

 

no electricity    

 

                     check cables, plugs                   

 

 

 

 

 

                     socket and fuse 

thermoprobe motor    

 

         deterrnine and remedy 

triggered  

 

 

 

         cause of overload  

pilot fuse defect  

 

          replace pilot fuse  
          find out cause if there  
          is a burn throuh again  

pump under pressure   

 

          trigger spray gun  

water leak  

 

 

 

 

packing worn or plunger pipe defect            replace  

pump does not reach pressure or  

 

water supply inadequate  

 

          open water tap  

is loud, pressure fluctations    

 

 

 

 

 

 

          check float valve  

clean water inlet sieve              
reduce height of suction  

suction valve clogged  

 

          rins pump with clear water  

soiled or wom valves, packing worn            clean or replace  
unloader valve leaky or soiled  

nozzle washed out or   

 

         replace  

wrong nozzle size  

oil leak on crankshaft   

 

 

shaft seal faulty  

 

 

       replace seal, scheck shaft  

incrased noise with no loss    

 

baring worn out  

 

 

       replace bearing,  

of 

pressure 

 

    change 

 

      interval to long  

pump oil milky white    

 

 

condensation water forrnation  

      reduce oil change  

      interval  

unloader valve tops at short    

 

gun or hp-hose leaky   

 

      seal, replace  

intervals with gun closed  

 

 

jack valve or unloader valve worn out      replace jach valve  

hight pressure gauge defection when  

unloader valve incorrectly set or foul       adjust unloader valve,  

gun 

closed 

 

          

 

 

 

 

 

replace 

 

Water volume to small  

 

 

wrong nozzle size  

 

 

      

use nozzle acc. to rating, plates         

nozzle dirty    

 

 

     clean or replace  

unloader valve too low  

 

     set sorrectly  

unloader valve faulty   

 

     replace  

Chemicals are not sucked in   

 

chemical tank emty    

 

     fill  

Summary of Contents for HWY118 EXT

Page 1: ...SPARE PART LIST Waschb r SE 112 118 HWY118 EXT Weidner Reinigungssysteme D 74523 Schw bisch Hall Steinbeisweg 29 Telefon 0791 95012 0 Fax 0791 54 742 e mail info weidner cleaning com Internet www weid...

Page 2: ...Implementing Order oft the Federal Pollution Protection Legislation to ensure that the immission limit values are observed 7 When operatingthe equipmentin rooms a safe discharge ofthe flue gases must...

Page 3: ...in our list of accessories We will be delighted to help you in the choice accessories and cleaning agents suitable for your cleaning needs 14 Befor working on the high pressure cleaner it must be disc...

Page 4: ...his control chain as an accessory If workis interruptedfor longerthan 1 minutes the device should be switched offto saveenergy The device is suitable to remove dirt from surfaces by means of a freely...

Page 5: ...sant hose to the injektor and place the suction filter into the cleansant The quantity of cleansant can be adjusted by turning the hand nut at the cleansant injektor If all the prenamed points are ful...

Page 6: ...m seperate drum turn the gwitch into the direction 2 If the cleangant tank drum is empty the metering valve should be closed pos since otherwise air will be sucked in and the working pressure will dro...

Page 7: ...ean or replace unloader valve leaky or soiled nozzle washed out or replace wrong nozzle size oil leak on crankshaft shaft seal faulty replace seal scheck shaft incrased noise with no loss baring worn...

Page 8: ...Chemical line blocked clean Chemical line faulty replace injector blocked clean injector faulty replace pressure adjustment nozzle too far open closed hp hose too long use a hose w nominal diameter 20...

Page 9: ......

Page 10: ...98 EPACA045891 3 Scheibe disk 99 EPACA104360 3 Plungerhalter plunger owner 100 EPACA0456812 3 Dichtungshalter kmpl seal owner 101 EPACA043302 3 lfilz oil felt 106 EPACA043305 3 ND Dichtung ND seal 12...

Page 11: ...800060 Brennkammer VA Waschb r SE combustion camber 4 ETB220102 Steckdeckel PVC Cover 5 35900001060 Sicherheitsthermostat 95 C mit Tauchh lse safety thermostat with dipping case 6 EPACA00300 Hochdruck...

Page 12: ...ngssysteme die sauberste L sung Pos No Bezeichnung Description 1418 3882800060 Brennkammer VA Waschb r SE combustion chamber 1423 3656040600 Einschraubheizk rper 403K 600 44 3 B G1 6000W heating unit...

Page 13: ...panel 6 ETE504300 Elektromotor 3 0 KW 400V 50Hz 1420 Electromotor 3 0 KW 400V 50Hz 1420 7 ETA200035 Schiebeb gel Waschb r ab 06 19999 handle Version after 06 1999 8 3914900010 Rohrschelle 22 mm Alumi...

Page 14: ...eating 7 ETE186200 Temperaturregler 0 95 C mit Tauchh lse temperature regulator with dipping case 8 ETA200035 Schiebeb gel Waschb r ab 06 19999 handle Version after 06 1999 9 ETA190100 1 Kantenschutz...

Page 15: ...steme die sauberste L sung HWY 118EXT_Schwimmerventil Pos No Bezeichnung Description 1305 3909900153 1 PVC Kunststoffschwimmer 65 x 130 pvc ball 65 x 130 1304 3909900103 1 Schwimmerventil 3 8 12mm 170...

Page 16: ...3 8 WE RST Sonder Winkelverschraubung hp fitting 9 5680301500 Schlaucht lle 1 2 AG x 6 mm low pr Fitting 1 2 AG x 6 mm 10 5680301350 T St ck 1 2 Mess AG x IG x IG T pc 1 2 11 ETA350040 4 Gummi Metall...

Page 17: ...minal block 8 3652251201 Schutzleiterklemme USLKG16N earth terminal 9 3652251110 Reihenklemme UKN16BU terminal block 10 3652251100 Reihenklemme UKN5BU terminal block 11 3652251200 Schutzleiterklemme U...

Reviews: