User Manual Managed Switches
42
3.3.12 Ext. Backup/Restore Module
The Weidmüller’s external backup and restore module IE-EBR-MODULE-RS232-ALM (Part No.
2682610000) is a standalone electronic unit that can be used to backup and restore the configuration
of managed Weidmüller switches. The device will be connected to the switch’s serial console port
and is powered via the console port.
This module allows the user to save and restore configuration files without PC. It is also a very useful
tool for creating cloned devices based on a stored Master Switch configuration to speed up mass
configuration.
The web page Ext. Backup/Restore Module allows the user to enable or disable the use of this
IE-EBR-MODULE-RS232-ALM module in the switch.
Backup Option
Setting
Description
Factory
Default
Disabled/Enabled
When Enabled, the IE-EBR-MODULE-RS232-ALM
can be used in the switch to download the
configuration file.
Disabled
Restore Option
Setting
Description
Factory
Default
Disabled/Enabled
When Enabled, the IE-EBR-MODULE-RS232-ALM
can be used in the switch to upload a stored
configuration file.
Disabled
3.3.13 Upgrade Firmware
This option is used to upgrade the firmware of the switch when a new version is available.
The page already shows the current firmware version stored on the switch. To import a new firmware
file into the Weidmüller switch, press the button
Select File
to select the firmware file that is saved on
your computer. The upgrade procedure will proceed automatically after pressing
Upgrade
.