3.6.4.6 CIST Ports
This page allows the user to inspect and change the current CIST port configurations.
For each port of the switch, the user can program the following parameters:
STP Enabled
Setting
Description
Factory Default
Checked /
Unchecked
Controls whether STP/RSTP is enabled on this switch
port.
Unchecked
Path Cost
Setting
Description
Factory Default
Auto / Specific
Configures the path cost incurred by the port.
Auto will set the path cost according to the physical link
speed by using the 802.1D-recommended values.
Specific allows the user to enter a user-defined value (1
to 200000000).
The path cost is used when establishing an active
topology for the network. Lower path cost ports are
chosen as forwarding ports in favor of higher path cost
ports.
Auto