User Manual Managed Switches
183
Event Types can be divided into two basic groups:
System Events
and
Port Events
. System Events
are related to the overall function of the switch, whereas Port Events are related to the activity of a
specific port.
NOTE:
For each event the user can decide if a log is registered (SYSLOG) and/or if a
warning Email is sent (SMTP). Please, consider that the SYSLOG and SMTP sever must
also be Enabled from the corresponding page.
System Events
Log is registered when / Warning e-
mail is sent when…
System restart
Weidmüller switch is rebooted.
Power Status
Weidmüller switch is powered up or down.
SNMP Authentication
Failure
Incorrect SNMP authentication.
O-Ring Topology Change
If the Master of the O-Ring has changed or the backup path is
activated.
O-Chain Topology Change
If the configuration of the O-Chain has changed or the backup
path is activated.
Configuration Changed
and Saved
Any configuration item has been changed and saved.
Port Events
Log is registered when / Warning e-
mail is sent when…
Disable
Never.
Link Up
The port is connected to another device.
Link Down
The port is disconnected (e.g., the cable is pulled out, or the
opposing device shuts down).
Link Up & Link Down
The port is either connected or disconnected.
3.13.2.2 Email Settings
E-mail Alert
Setting
Description
Factory
Default
Enabled or
Enable or disable the Email warning function.
Disabled