User Manual Managed Switches
163
Filter: Frames matching the ACE are filtered.
Rate Limiter
Indicates the rate limiter number of the ACE. The allowed range is 1 o 16.
When Disabled is displayed, the rate limiter operation is disabled.
Mirror
Indicates if the Mirror operation is included in the ACE (Enabled). When
Disabled is displayed, the mirror operation is disabled.
CPU
Forward packet that matched the specific ACE to CPU.
Counter
The counter indicates the number of times the ACE was hit by a frame.
Conflict
Displays ‘Yes’ if there is a HW conflict related with the created ACE.
Otherwise displays ‘No’.
3.12.4 Authentication, Authorization and Accounting (AAA)
For user name/password level security, Weidmüller switches provide the possibility to enable/disable
any possible access to the management of the device and also provide the login option through
Remote Access Dial-In User Service (RADIUS) or Terminal Access Controller Access-Control
System Plus (). The RADIUS and mechanisms are
centralized “AAA”
(Authentication, Authorization and Accounting) systems for connecting to network services.
In the following sections of this chapter the different configuration options for RADIUS and
operation are described.
NOTE:
The Authentication, Authorization and Accounting preferred options for the switch (including
RADIUS and ) are selected in the web page Authentication methods of the Basic
Settings menu.
3.12.4.1 RADIUS Server Configuration
This page allows the user to configure the RADIUS servers.
Global Configuration
Timeout
Setting
Description
Factory
Default
1 to 1000 (sec)
Number of seconds to wait for a reply from a RADIUS
server before retransmitting the request.
5