User Manual Managed Switches
97
View Type
Setting
Description
Factory
Default
Included
Indicates that the created view subtree should be
included.
Exact
Excluded
Indicates that the created view subtree should be
excluded.
OID Subtree
Setting
Description
Factory
Default
Number (OID)
The object identifier (OID) value for the created view
table. The allowed OID length is 1 to 128. The
allowed string content is digital number or asterisk
(*).
None
3.8.7 SNMP Access Configuration
NOTE:
This page only has to be configured if SNMPv3 is programmed in the switch.
This page allows the user to configure SNMPv3 accesses table. The entry index keys are Group
Name, Security Model and Security Level.
Two default views are already created but is possible to create additional ones based on the
SNMPv3 users / groups / views created. Press the button
Add New Entry
to create a new Access.
Group Name
Setting
Description
Factory
Default
Max. 32
characters
A string identifying the group name that this entry
should belong to. It should be one of the created
groups in the SNMP Groups Configuration option.
None
Security Model
This Security Model must be selected in accordance with the one defined for the User of the selected
Group Name.
Setting
Description
Factory
Default
V1
Reserved for SNMPv1.
any