www.wegener.com
800072-01 Rev. A
33
Unity 550 User’s Manual
A
PPENDIX
A: T
ERMINAL
/M
ODEM
M
ODE
Terminal/Modem Commands
Commands listed in this section detail command syntax and action taken. Commands
consist of a command field and a parameter field. Each command field and parameter field
is separated from others by a space. Optional parameters are indicated by square brackets,
[ ], and conditional parameters are indicated by braces, { }.
For example, COMMAND_NAME parameter1 {parameter2} [parameter3] indicates that
parameter1 must be entered, parameter2 entered only when a certain condition is met
(certain option is installed, etc.), and parameter3 is optional. Both commands and
parameters may be entered in upper or lower case; the interface is not case-sensitive.
Incorrect or incomplete commands result in Invalid Command responses being displayed at
the terminal. Parameter errors on User commands generate Invalid parameter name
responses, where parameter name is the name of the incorrectly entered parameter.
Network-
Enabled Local
Control
Commands
These commands are allowed only if local control is enabled and are listed in
Table A.1
below. Commands that are always functional are discussed in
Local Control Commands
on page 35 and listed in
Table A.2
.
Table A.1: Unity 550 Network-Enabled Local Control Commands
ABORT
Insert is terminated. See TEMP command.
ADDS location settings
location
:
Value from 1 - 48 indicating location in settings_table.
settings
: See
Section 4.1 Perms/Temps/Searching & Settings
on page 25
The settings are added to the settings_table at the specified location. Will also handle data rate
rounding as explained for PERM.
AUXDATA [PID] [baud] [parity]
PID:
Selects the PID (in hex) for the Transport packets carrying the desired data stream. Must
be 20 to 1FFE inclusive.
baud:
Selects the baud rate of the async data stream. Normally 19200.
parity
:
Sets the parity for the data output. Normally None.
Sets up the Aux Data serial port device.
DELS location
location:
Value from 1 to 48 indicating location in the settings_table.
The entry in the settings_table at the specified location is deleted. The command is ignored if the
settings_table contains only one entry.
MUTE [source][source]
Summary of Contents for UNITY 550
Page 6: ...Unity 550 User s Manual 2 800072 01 Rev A www wegener com...
Page 8: ...Unity 550 User s Manual 2 800072 01 Rev A www wegener com...
Page 14: ...Chapter 1 General Information 8 800072 01 Rev A www wegener com...
Page 18: ...Chapter 2 Installation 12 800072 01 Rev A www wegener com...
Page 30: ...Chapter 3 Operation 24 800072 01 Rev A www wegener com...
Page 38: ...Chapter 5 Customer Service 32 800072 01 Rev A www wegener com...
Page 56: ...50 800072 01 Rev A www wegener com...
Page 57: ......