Autosteamer temperature probe disconnected.
Autosteamer probe in short circuit.
Autosteamer probe overheating.
Check for proper connection of the autosteamer probe and
replace it if necessary.
Service boiler heating circuit disconnected.
Heating element protection thermostat open.
Check steam boiler heating circuit and replace burned compo-
nents if necessary.
HEATING TIMEOUT GROUP ON
GROUP #
Heating circuit group on group disconnected.
Group heating element interrupted.
HEATING OUT OF SERVICE
GROUP ON GROUP #
Heating circuit group on group disconnected.
Group heating element interrupted
COFFEE WATER HEATING
TIMEOUT ON GROUP #
Water boiler heating circuit on group disconnected.
Group water boiler heating element interrupted.
Fuse(s) F2 - F3 - F8 - F9 burned.
COFFEE WATER HEATING OUT OF
SERVICE ON GROUP #
Water boiler heating circuit on group disconnected.
Group water boiler heating element interrupted.
Fuse(s) F2 - F3 - F8 - F9 burned.
The service boiler has not completed the filling
within the maximum time (255 seconds).
The level probe does not detect the presence of
water.
Check hydraulic circuit for service boiler water filling:
Check that there is actually water in the mains water supply.
Check filling solenoid valve / pump filter
Check fuse F3 on control unit.
The service boiler has not completed the filling
within the maximum time (90 seconds).
Check hydraulic circuit for service boiler water filling:
Check that there is actually water in the mains water supply.
Check filling solenoid valve / pump filter
Check fuse F3 on control unit.
The water in the service boiler has dropped below the
minimum level.
Check for correct connection of the minimum level probe.
COFFEE WATER PRESSURE ON
GROUP #
The service boiler has not reached the filling pressure
within the maximum time (60 seconds).
Check coffee boiler hydraulic circuit:
Check that there is actually water in the mains water supply.
Check solenoid valve / pump filter.
Check volumetric dosing device (filter input / 0.5mm gigler
output).
The volumetric dosing device does not perform water
count.
Check the volumetric dosing device connection.
Check that there is actually water in the mains water supply.
Summary of Contents for Wegaconcept
Page 1: ...ESPRESSO COFFEE MACHINE Use and maintenance manual for the TECHNICIAN ENGLISH Wegaconcept...
Page 3: ...English...
Page 7: ...7 Wegaconcept Technical manual ENGLISH Section I Operation...
Page 58: ...58 Wegaconcept Technical manual 33 Electric diagrams 33 1 Electronic control unit diagram...
Page 60: ...60 Wegaconcept Technical manual 33 2 Electronic control unit Diagram Rev 01...
Page 69: ...69 Wegaconcept Technical manual ENGLISH Section IV Interfaces...
Page 75: ......