ALL THE LEDS OF ALL THE PUSH BUTTON
PANELS ARE FLASHING
After a few minutes, automatic filling with water is
stopped:
The tap for the automatic level device is closed.
Some of the hoses in the circuit are clogged.
The probe and/or the mass are disconnected.
Turn the machine off and then back on.
Open the automatic level device tap.
Check and replace the defective hoses.
Check and restore the connections.
SHUTDOWN OF THE ELECTRONIC SYSTEM
The control unit fuse F4 is burned out.
One of the volumetric dosing device's contacts is
grounded
Check the connection of the volumetric dosing device
Poor mechanical grip of the shaft or O-Ring seal.
The inlet and outlet connections are loose.
The hex nut of the pressure relief valve or filter is loose.
The seal or O-Ring of the pressure relief valve or filter
is faulty.
Check the status of the pump and take any corrective
action which may be required.
Tighten the hex connection of the pressure relief
valve and filter.
Replace the seal and O-Ring, taking care not to change
the calibration of the valve.
THE MOTOR STOPS SUDDENLY OR THE
THERMAL PROTECTOR INTERVENES DUE
TO OVERLOAD
Lime scale and mineral build-ups in the pump have
caused it to jam.
The pump and motor are not aligned.
The motor is wired with non-conforming voltage.
Check the status of the pump and replace it, if neces-
sary.
Ensure the power supply voltage of the motor is
correct.
THE PUMP FUNCTIONS BELOW NOMINAL
CAPACITY
The inlet is clogged, perhaps only partially.
The rotation sense of the pump is incorrect.
The pressure relief valve is not properly calibrated.
The inside of the pump is damaged due to the infiltra-
tion of foreign materials.
Check the voltage or replace the motor.
The pump and motor are not aligned.
The seal or O-Ring of the pressure relief valve or filter
is faulty.
The joint, the coupling screw or the V-shaped clamp
are loose.
The inlet is clogged, perhaps only partially.
The hex nut of the pressure relief valve or filter is loose.
Replace the seal and O-Ring, taking care not to change
the calibration of the valve.
Align and tighten the components which are loose.
Tighten the hex connection of the pressure relief
valve and filter.
THE CUP IS DIRTY WITH SPLASHED
COFFEE
Steam pockets in the delivery system.
Air pockets in the hydraulic circuit.
Summary of Contents for Wegaconcept
Page 1: ...ESPRESSO COFFEE MACHINE Use and maintenance manual for the TECHNICIAN ENGLISH Wegaconcept...
Page 3: ...English...
Page 7: ...7 Wegaconcept Technical manual ENGLISH Section I Operation...
Page 58: ...58 Wegaconcept Technical manual 33 Electric diagrams 33 1 Electronic control unit diagram...
Page 60: ...60 Wegaconcept Technical manual 33 2 Electronic control unit Diagram Rev 01...
Page 69: ...69 Wegaconcept Technical manual ENGLISH Section IV Interfaces...
Page 75: ......