Brine Nebulization System, Type Soldos V3
Index: 03
Change date: 01/03/2017
Operating instructions no.: BA DW 005-03 Soldos V3 EN.docx
Page 22 of 70
5.2.1.2
Activate disinfection and rinsing
1.
Connect the nozzle adapter (19) of the disinfection set supplied (18) to the
nozzle in the appropriate room and duct the exuding disinfecting solution into
one of the plastic containers or directly into the floor drain.
CAUTION !
Ensure that no persons remain in the respective room.
2.
Press the OK button to activate disinfection.
3.
The dosing pump starts up and the disinfection solution is transported through
the whole system. The disinfection time is 90 seconds per 10m of hose length.
The disinfection data are shown.
Pressure 2 optional
The exposure time (11 min) is shown.
The disinfection program is completed once the exposure time has expired.
The disinfection has to be repeated when a fault message occurs.