Brine Nebulization System, Type Soldos V3
Index: 03
Change date: 01/03/2017
Operating instructions no.: BA DW 005-03 Soldos V3 EN.docx
Page 20 of 70
3.
Fill the empty bottle provided with the disinfection set (18) with water. The
amount of water depends on the length of the dosing line from the nozzle to
the room wall.
Add 200 ml of water per started 10-m hose section to the bottle and add
one SOLDOS disinfection tablet, Item No. 19871, per 200 ml of water.
For example, when the pipe is 11m long, fill 400ml of water into the bottle
and add 2 disinfection tablets.
Shake the bottle until the tablet(s) are dissolved.
Thereafter, press the OK button.
HINT !
The polyethylene container is already connected when the device is
delivered to protect it from pollution.
4.
Unscrew the polyethylene container lid and pour the disinfection solution from
the bottle into the polyethylene container. Thereafter, press the OK button.
5.
Reconnect the polyethylene container filled with disinfection solution and place
it onto the bracket. Proceed as described in the following section to do this.