Technical data
Soldos V3
Item no.
Dimensions and weights:
External dimensions
47 x 71 x 24cm (width x height x depth)
Space requirements incl. operation
and maintenance
100 x 200 x 100cm
(width x height x depth)
Empty weight / operating weight
Approx. 15kg / 16kg
Connection data
Electrical connection data
230V AC, 50Hz, 0.05kW, two-pin earthed
plug
Hydraulic connection data
---
Drain connection required
---
Protection class
IP44
Nominal pressure / operating
pressure
PN16 / max. 11barg
Operating data:
Brine volume in polyethylene
container
5l
Brine nebulising capacity
100ml/min
Medium temperature
5°C to 35°C
Ambient temperature
5°C to 35°C
Humidity in utility room
Max. 70%
Degree of saturation of the brine
mist
Max. 5% at the nozzle outlet
Ventilation and extraction
Recommended for the utility room
Software version
---
Hardware version
V1.1
3.5
Transport / storage
The device must be checked for possible transport damage immediately after
receipt.
Attention !
The device can get damaged by frost or high temperatures. Prevent
exposure to frost during transport and storage! Do not store the
device next to objects with high heat radiation or directly exposed
to sunlight. The device may only be transported and stored in its
original packaging. Careful handling must be ensured.