Starting the Compressor
For a quick key reference please open the Operator Panel folder in the end of this manual.
By pressing the pump start key K3 the Compressor will start, the refrigeration set point screen will be
displayed and the LED L3 will light up.
By pressing K3 once more the compressor will stop and L3 will turn off.
If any of the following faults are detected the compressor will not start but an error message will
displayed instead. The faults are the following:
Error 2: Compressor Breaker Tripped
Error 6: Error in Mains Supply
Error 9: Compressor Overheated
Error 10: High Condenser Pressure
Error 11: Compressor Oil Pressure Low
For a closer description of the error see the alarm section.
If these alarms occur when the compressor is running it will shut down, L3 will turn off and the relevant
alarm message will be displayed.
Screen field description:
1
This is the opening of the backpressure valve in percent.
2
The bar graph is showing the opening of the backpressure valve in percent
To increase the setpoint press K9 (Arrow Right). To decrease the setpoint press K6 (Arrow Left).
Pressing the K5 (Escape) will display the main menu screen on the display.
Pressing the K10 (Enter) will display the next production screen on the display and at the same enable
the automatic production page scroll-function.
1