![WCB Ice Cream MF Operating Manual Download Page 7](http://html1.mh-extra.com/html/wcb-ice-cream/mf/mf_operating-manual_878932007.webp)
MF Freezer
Operating manual
WCB Ice Cream
7-29
Starting the Dasher
For a quick key reference please open the Operator Panel folder in the end of this manual.
By pressing the pump start key K2 the dasher will start, the dasher monitor screen will be displayed
and the LED L2 will light up.
By pressing K2 once more the dasher will stop and L2 will turn off.
If any of the following faults are detected the pumps will not start but an error message will displayed
instead. The faults are the following:
Error 3: Dasher Breaker off
Error 6: Error in Mains Supply
For a closer description of the error see the alarm section.
If these alarms occur when the dasher is running the dasher will shut down L2 will turn off and the
relevant alarm message will be displayed.
If the Dasher load is exceeding the motor load warning threshold an alarm will be displayed and the
back pressure valve will reduce its opening by 10 percent.
If the dasher load is exceeding the motor load shut down limit, the dasher will stop and an alarm will
be displayed.
Screen field description:
1. This field indicates the current consumption of the dasher motor in Amps.
2. This field indicates the current consumption of the dasher in percent of full motor amperage.
3. The bar graph is showing the current consumption of the dasher in percent of full motor
amperage
This screen is a monitor screen only and it is not possible to adjust the motor load.
Pressing the K5 (Escape) will display the main menu screen on the display.
Pressing the K10 (Enter) will display the next production screen on the display and at the same enable
the automatic production page scroll function.
1
2
3