![WCB Ice Cream MF Operating Manual Download Page 28](http://html1.mh-extra.com/html/wcb-ice-cream/mf/mf_operating-manual_878932028.webp)
MF Freezer
Operating manual
WCB Ice Cream
28-29
Using the Test Mode
The test mode is intended for use in troubleshooting and testing the freezers PLC, motor and
actuators.
Before you go into test mode be sure that no freezers functions are running. If for instance the pumps
are running the change to test mode will be blocked and an alarm will be displayed.
Then go to the maintenance screens as described in the previous chapter and key in the Master pass
code.
A successful transfer to test mode is indicated by the message field (1) changing from “Check” to
“Testing”
Now it is possible to alter the status of the digital and analog outputs.
If you press K6 (Arrow Left) and K9 (Arrow Right) you will move the cursor (1) and at the same time
you will get an explanation of what the output is for in the message field (2)
If you press K7 (Arrow Up) you will change the status of the digital output from “off” to “on”. If you
press K8 (Arro
w Down) you will change the status from “On” to “Off”.
If you want to change an analog output value find the correct screen and then press K7 (Arrow Up) to
increase the analog output value and press K8 (Arrow Down) to decrease the analog output value.
You exit from Test mode by entering the master pass code again. The message field (1) will change
from
“Testing” to “Check” and the digital and analog values will resume the status they had before the
change to test mode was done.
1