Dasher Parameters
By pre-selecting the Dash Field on the Main Set-up Menu and pressing K10 (Enter) you will get into
the first of the adjustable Dasher Parameters.
Dasher Load Warning Threshold
On this screen you set the load warning threshold. When the dasher is running the control system is
supervising the load of the dasher. When the load is exceeding this threshold an alarm is displayed
and the Back Pressure Valve opening is reduced by 10 percent in order to bring down the dasher
load.
When the load has dropped 5 % below the warning threshold the Back Pressure Valve is returned to
its original opening.
By pressing K7 (Arrow) up you increase the parameter and by pressing K8 (Arrow Down) you
decrease the parameter. Keeping the keys pressed will make the adjustments go faster and faster.
The parameter adjustment is immediately being stored. There is no need for acknowledging the
adjustment.
If you press K5 (Escape) you will return to the Main Set-up Menu. By pressing K10 (Enter) you will go
to the next adjustable Dasher Parameter:
Dasher Max Load
On this screen you set the maximum allowable load of the dasher. When the dasher is running the
control system is supervising the load of the dasher. When the load is equal to or exceeds this
parameter an alarm is displayed and refrigeration and dasher is stopped.
By pressing K7 (Arrow) up you increase the parameter and by pressing K8 (Arrow Down) you
decrease the parameter. Keeping the keys pressed will make the adjustments go faster and faster.
The parameter adjustment is immediately being stored. There is no need for acknowledging the
adjustment.
If you press K5 (Escape) you will return to the previous Dasher parameter. By pressing K10 (Enter)
you will go to the next adjustable Dasher Parameter: