A. To clear the error message it is necessary to either cycle the power to the Duplex Computer or enter
option 99, change the data to 3 and exit option programming. Even if the problem is corrected the fault
code will continue to be displayed until one of these procedures is executed.
TABLE 6-13. FAULT CODE 03.
Probable Cause
Corrective Action
Unit has run over preset/prepay amount.
1.
Solid state relay on solenoid drive board
shorted.
Check for 110VAC output (24VDC for blenders) to valve(s)
with handle off. If 110VAC (24VDC for blenders) is present,
replace solenoid drive board.
2.
Debris in diaphragm valve, actuator, or
proportional flow control valve.
Check/clean all valves.
3.
Defective diaphragm valve (non-blender
only).
Install diaphragm service kit.
4.
Defective actuator (non-blender only).
Replace actuator.
5.
Defective computer.
Replace computer assembly.
6.
Defective proportional flow control valve
(Blenders only).
Replace proportional flow control valve.
TABLE 6-14. FAULT CODE 04.
A
Probable Cause
Corrective Action
ROM error.
1.
Computer found defective ROM chip dur-
ing self test.
Clear error. If problem reoccurs replace computer assembly.
Summary of Contents for Dresser Vista 1 Series
Page 1: ...1 Vista Series Blending and Non Blending Remote Dispensers SERVICE ...
Page 4: ...Part No 920160 Rev A February 1997 ...
Page 10: ...viii Part No 920160 Rev A February 1997 ...
Page 12: ...2 Part No 920160 Rev A February 1997 ...
Page 22: ...12 Part No 920160 Rev A February 1997 ...
Page 38: ...28 Part No 920160 Rev A February 1997 ...
Page 62: ...52 Part No 920160 Rev A February 1997 ...
Page 76: ...66 Part No 920160 Rev A February 1997 FIGURE 7 8 NOZZLE BOOT ASSEMBLY LIFT TO START ...
Page 77: ...67 February 1997 Part No 920160 Rev A FIGURE 7 9 NOZZLE BOOT ASSEMBLY PUSH TO START ...
Page 83: ...73 February 1997 Part No 920160 Rev A APPENDIX A TROUBLESHOOTING FLOWCHARTS ...
Page 110: ...100 Part No 920160 Rev A February 1997 ...
Page 111: ...101 February 1997 Part No 920160 Rev A APPENDIX B SERVICE INFORMATION AND CONNECTOR PIN OUTS ...
Page 134: ...124 Part No 920160 Rev A February 1997 ...
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 141: ......
Page 142: ......
Page 143: ......
Page 144: ......
Page 145: ......
Page 146: ......