background image

5. Protect electrical cord from sharp

objects, hot surfaces, oils, and chemicals.
Avoid kinking the cord and replace
damaged cords immediately.

IMPORTANT: 

Make sure there is adequate

room for the switch to operate.
6. A sump pit cover must be installed to

prevent debris from clogging or
damaging the pump or interfering with
pump.

Operation

Always disconnect the
power source before
attempting to install,
service, relocate or maintain the pump.
Never touch sump pump, pump motor,
water or discharge piping when pump
is connected to electrical power. Never
handle a pump or pump motor with
wet hands or when standing on wet or
damp surface or in water. Fatal
electrical shock could occur.

1. A ground fault circuit interrupter (GFCI)

is required.

Risk of electrical 
shock! This pump is

supplied with a grounding conductor
and grounding type attachment plug.
Use a grounded receptacle to reduce
the risk of fatal electrical shock.
Never cut off the round grounding
prong. Cutting the cord or plug will
void the warranty and make the pump
inoperable.

Installation

1. Install pump in a sump pit with minimum

size as shown in Figure 1. Construct sump
pit of tile, concrete, steel or plastic.

2. The unit should be located and rest on

a solid, level foundation. Do not place
pump directly on clay, earth, gravel or
sandy surface. These surfaces contain
small stones, gravel, sand, etc. that may
clog or damage the pump and cause
pump failure.

Flood risk. If

flexible discharge

hose is used, make sure pump is
secured in sump pit to prevent
movement. Failure to secure pump
could allow pump movement and
switch interference and prevent pump
from starting or stopping.

3. Thread check valve (Blue Angel™ offers

Model 66005-BLA1) into pump body
carefully to avoid stripping or cross
threading. Do not use pipe joint sealant.

4. Connect 1-1/2" rigid pipe to rubber boot

on check valve. Reverse boot for 1-1/4"
diameter pipe. Tighten hose clamps.

Support pump and
piping when

assembling and after installation.
Failure to do so could cause piping to
break, pump to fail, etc. which could
result in property damage and/or
personal injury.

Please read and save these instructions. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by
observing all safety information. Failure to comply with instructions could result in
personal injury and/or property damage! Retain instructions for future reference.

Description

The submersible pump is designed for
indoor home sump applications. The unit is
equipped with an 8-ft long, 3-prong
grounding type power cord. Motor is oil
filled and sealed for cooler running and
designed to operate under water. A float
switch is provided for automatic pump
operation. This pump is not suitable for
aquatic life.

General Safety
Information

Do not use to pump
flammable or explosive
fluids such as gasoline, fuel oil,
kerosene, etc. Do not use in a
flammable and/or explosive
atmosphere. Pump should only be used
to pump clear water. Personal injury
and/or property damage could result.

This pump is not 

designed to handle

salt water, brine, laundry discharge or
any other application which may
contain caustic chemicals and/or
foreign materials. Pump damage could
occur if used in these applications and
will void warranty.

All wiring must be 
performed by a

qualified electrician. Failure to follow
this warning could result in fatal
electrical shock.

If the basement has water
or moisture on the floor,
do not walk on wet area
until all power is turned off. If the
shutoff box is in the basement, call an
electrician. Remove pump and either
repair or replace. Failure to follow this
warning could result in fatal electrical
shock.

A backup system 

should be used.

Blue Angel™ offers Model BSP15 and
BSP25

Operating Instructions and Parts Manual

BRSPT130

350800-002  1/07

Tether

14"

Min. Diameter

Submersible Sump
Pump

14"

Figure 2

Grounded
Outlet

24"

Figure 1

For parts, product & service information

visit 

www.blueangelpumps.com

© 2007 Blue Angel™ Pumps

Summary of Contents for 350800-002

Page 1: ...e clamps Support pump and piping when assembling and after installation Failure to do so could cause piping to break pump to fail etc which could result in property damage and or personal injury Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failur...

Page 2: ...but delivers little or no water 1 Blown fuse 2 Low line voltage 3 Defective motor 4 Defective float switch 5 Impeller bound up 6 Float obstructed 1 Backflow of water from piping 2 Faulty float switch 1 Defective float switch 2 Obstacle in piping 3 Float obstructed 1 Low line voltage 2 Plugged impeller 3 Obstructed piping 4 Excessive lift height water has to go higher than pump can handle 1 If blow...

Page 3: ...101 Production Drive Harrison OH 45030 U S A Replacement Parts List Only use factory parts to repair this pump 1 2 www blueangelpumps com Specifications Power supply requirements 120V 60 hz Motor Single phase oil filled Liquid temperature range 40 F to 120 F Circuit requirements 15 amps min Dimensions 11 high x 9 base Cut in level factory set Tether 14 Cut out level factory set Tether 7 Constructi...

Page 4: ...ns on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to you This limited warranty gives you specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwis...

Page 5: ...Un interrupteur flotteur est fournit pour le fonctionnement automatique Cette pompe n est pas convenable pour les animaux aquatiques Généralités Sur La Sécurité Ne pas pomper les fluides explosifs tels que l essence l huile à chauffage le kérosène etc Ne pas utiliser dans un atmosphère inflammable et ou explosif La pompe devrait être utilisée pour le pompage de l eau claire seulement sinon il y a ...

Page 6: ... taille correcte ou rajuster le disjoncteur 2 Si la tension est sous 108 volts vérifier la taille des fils 3 Remplacer la pompe 4 Remplacer l interrupteur flotteur 5 Si la turbine ne tourne pas enlever le carter et enlever l obstruction 6 Assurer le movement libre du flotteur 1 Installer ou remplacer le clapet Jeu de clapet Wayne 660005 WYN 2 Remplacer l interrupteur flotteur 1 Remplacer l interru...

Page 7: ... Turbine 28541 001 4 Attache de retenue de la turbine 67106 001 Nº de Numéros de Pièces Réf Description RSP 130 1 2 Spécifications Exigences d alimentation 120 V 60 Hz Moteur Monophasé rempli d huile Gamme de température de liquides 4 5º C à 49 3º C Exigence de circuit 15 A min Dimensions Hauteur 27 94 cm x Base de 22 86 cm Niveau de démarrage réglé à l usine Longe 35 56 cm Niveau d arrêt réglé à ...

Page 8: ...e limitations de durée pour les garanties implicites ni l exclusion ni la limitation des dommages fortuits ou indirects Les limitations précédentes peuvent donc ne pas s appliquer Cette garantie limitée donne à l acheteur des droits légales précis et vous pouvez avoir autres droits légales qui sont variable d une Province ou d un État à l autre En aucun cas soit par suite d un rupture de contrat d...

Page 9: ...vula de chequeo Wayne le ofrece el Modelo 66005 WYN a la bomba Cerciórese de atornillarla adecuadamente No use pegamento cola en las conexiones 4 Conéctele una tubería rígida de 0 38 cm 1 1 4 a la pieza de goma de la válvula de chequeo Invierta la pieza de goma para conectarla a las tuberías de 0 45 cm 1 1 2 de diámetro Apriete las abrazaderas de la manguera Tanto la bomba como las tuberías se deb...

Page 10: ...es muy bajo 2 El impulsor está obstruído 3 Tubería obstruida 4 Altura de elevación excesiva el agua debe subir a una altura más elevada de lo que la bomba puede alcanzar 1 Si se quemó reemplácelo con un fusible adecuado o conecte el cortacircuito 2 Si el voltaje es menos de 108 voltios chequée el alambrado 3 Reemplace la bomba 4 Reemplace el flotante interruptor 5 Si el impulsor no gira destápelo ...

Page 11: ...retención del impulsor 67106 001 No de Número de Piezas Ref Descripción RSP 130 1 2 Especificaciones Requerimientos eléctricos 120 Voltios 60 Hz Motor Monofásico con aceite Temperaturas del líquido 4 5º C à 49 3º C Circuito eléctrico 15 amperios mínimo Dimensiones 27 94 cm alto X 22 86 cm base Nivel de encendido fijado de fábrica Ronzal 35 56 cm Nivel de interrupción fijado de fábrica Ronzal 17 78...

Page 12: ...CUENCIA DE DAÑOS SON EXCLUIDAS Algunos estados no permiten límites en la duración de las garantías o no permiten que se limiten o excluyan casos por daños por accidentes o consecuentes en dichos casos los límites arriba enumerados tal vez no apliquen para Ud Esta garantía limitada le otorga a Ud ciertos derechos que pueden variar de un estado a otro Bajo ninguna circunstyancia aunque sea debido al...

Reviews: