In this chapter
˽ Click 112/114 Contact Closure Cards
˽ Click 172/174 Contact Closure Cards
˽ Click 104 DIN Rail Module
12
Once the sensor has been installed and configured, the detections will be recorded in a con-
troller through the use of contact closure modules. The Click 112/114 and 172/174 cards
are specifically designed to easily integrate the SmartSensor Advance with existing NEMA
TS1, TS2, 170 and 2070 controllers.
Click 112/114 Contact Closure Cards
You can use SmartSensor Advance and SmartSensor Advance Extended Range with the
Click 112/114 contact closure cards using the Z4 protocol. Communication from the sen
-
sor can be set up by the cards or by using SmartSensor Manager.
To connect and autobaud to the detector rack cards:
1
Connect from the Click 222 RS-485 A port to a bus 1 port on the appropriate rack
card. Connect from the Click 222 RS-485 B port to a bus 1 port on another rack card.
2
If you are using Click 112 cards, use a patch cord to share bus 1 between cards dedi-
cated to the same sensor. If you have more than two sensors in your system, repeat steps
1–3 to connect bus 1 for all remaining rack cards.
3
Connect from a Click 222 bridge port to bus 2 of the rack cards.
4
Daisy-chain between the bus 2 ports of all of the rack cards for device configuration.
5
Verify that detections are registering on the Channel LEDs.
Programming Contact Closures
12