The “ATM Layer QoS (SVC) - Calling” test type
This test type is intended for ATM layer QoS measurements with switched virtual connections
where channels are to be tested from end to end in both directions. Two test instruments are
needed for the test, one acting as calling party and the other as called party. The instrument
configured with this test type is the calling party.
This test is particularly effective in determining adherence to traffic contracts.
5.7
The “ATM Layer QoS (SVC) - Called” test type
This test type is intended for ATM layer QoS measurements with switched virtual connections
where channels are to be tested from end to end in both directions. Two test instruments are
needed for the test, one acting as calling party and the other as called party. The instrument
configured with this test type is the called party.
This test is particularly effective in determining adherence to traffic contracts.
When the instrument accepts the call, it automatically configures its transmitter according to the
contract parameters contained in the incoming Setup Message. The instrument then starts
generating traffic (if traffic generation has been enabled by the user) and measuring the QoS
parameters. Traffic generation ceases after the call is cleared down.
The instrument can be called as often as is required, but it can accept a maximum of four calls
at one time. The calls can come from different (ANT-20) instruments at the far end operating in
“Calling” mode.
The signaling processes and connection states are saved in a log file and displayed in the “ATM
Test Results”. The measured QoS parameters can also be saved optionally in the log file.
Characteristics
•
Measurement of switched virtual connections (SVC)
•
Up to four virtual channels possible
•
Cell delay measurements are not possible
•
Bi-directional, symmetrical or asymmetric channels
can be tested.
Basic instrument settings
•
“Emulate” topology
•
Signaling emulation “on”
The pictogram shown opposite appears in the workspace
of the VI.
Tip:
Configurations using more than two test
instruments are also possible.
Summary of Contents for ANT-20
Page 8: ...Broadband Analyzer Generator ANT 20 ANT 20E vi Notes ...
Page 64: ...Broadband Analyzer Generator ANT 20 ANT 20E O 46 Operation Notes ...
Page 110: ...Broadband Analyzer Generator ANT 20 ANT 20E TB 16 Technical Background Notes ...
Page 126: ...Broadband Analyzer Generator ANT 20 ANT 20E iv Notes ...