WIFI232-B2 User Manual
99
/
102
Q6: How to avoid IP address confliction when apply WIFI232 module?
A6:
The following address allocation method can avoid the IP address confliction for
dynamic and static IP address mixed application.
➢
Module dynamic IP address range from 100 to 200 for last IP address segment.
Such as default IP: 10.10.100.254. When module works as AP, the IP address
module can allocate to STA is from 10.10.100.100 to 10.10.100.200;
So, if user needs to set static IP for dedicated STA internal network, the
available IP address range can start from 10.10.100.1 to 10.10.100.99
Q7: PC works as server, all WIFI modules works as data acquisition card and
connect with PC, how to configure this application?
A7:
Network structure as below figure: Three WIFI232 module setup 3 TCP links with PC
server. Module 1# works as AP and all devices connect to module 1# through WiFi
interface;