WIFI232-B2 User Manual
72
/
102
Format:
AT+EPHY=<on/off><CR>
+ok<CR><LF><CR><LF>
Parameters:
To reduce the consumption, the Ethernet port is closed by default. With this
command, the Ethernet port will be opened immediately, and it is invalid after restart. If
you want to open the Ethernet permanently, please use he command AT+FRPHY=on.
We recommend you to close the port for reducing consumption.
Use command AT+FVEW=disable/enable and switch the module to work at LAN
port (disable) or WAN port (enable). It is effective after restart.
5.2.1.30 AT+FUDLX
Function:
Enable/Disable RS485
Format:
AT+FUDLX=<on/off><CR>
+ok<CR><LF><CR><LF>
Note:
This command is used to enable or disable the RS485 function. RS485 is default
closed. The control pin of RS485 is RTS. The setting is effective after restore factory
setting.
5.2.1.31 AT+MMID
Function:
Set ID of module
Format:
AT+MMID=<ID><CR>
+ok<CR><LF><CR><LF>
Parameters:
ID: 0~65535
5.2.1.32 AT+IDFIR
Function:
Enable/Disable
“Send an ID when module connection is established” function
Format: