TCP connecting password authentication: When the WIFI232 work in TCP Server
mode, it will authenticate the password of client which connected.
Note:
This authentication only works when the module is set as TCP server. After
opening this function, the fist data sent to module is password plus newline when TCP
client connect to TCP server of module. The password is default “admin” which is used
to login web. For example, the first data is “0x61 0x64 0x6D 0x69 0x6E 0x0D 0x0A” (HEX)
4.9.8
Ethernet Setting
This page is used to set Ethernet port of module. The Ethernet port can be opened
or closed. And can be configured as WAN port. So the module can work as secondary
router, making it easy for users to network. The specific setting page is as below:
Figure 34 Ethernet Setting Page
4.9.9
HTTD Client Mode
This page sets the HTTP header in the HTTPD Client mode. Including: the address
pf the server, the server port, request type, protocol header path, protocol header
Connection and protocol header User-Agent.
HTTPD Client Mode supports POST, PUT and GET three HTTP request types. With
POST and PUT type, serial data will be followed the HTTP header. If the request is GET,
serial data will be followed path of HTTP header. The specific way of sending data can
consult section 4.2.4