3.2
Default settings
The following table shows the different storable parameters, the
command to store them and there default value.
Command
Command
AT&W
AT&W (E2P)
(E2P)
AT+CSAS
AT+CSAS
(SIM, E2P)
(SIM, E2P)
Default value
Default value
+CMEE
X
0
+CSCS
<char. set>
"PCCP437"
ATS0
<# of Ring>
0 (no auto-answer)
+CICB
X
2 (speech)
+VGR
<n>
2 (all speakers)
+VGT
<n>
2 (all microphones)
+SPEAKER
X
0 (Speaker 0 & Micro 0)
+ECHO
All
160, 12, 5, 512, 10
+SIDET
X
1,1
+CREG
<mode>,<form>
0
+CLCK
X
No SIM or Network lock
+CPWD
<pwd>
00000000 (SIM & Net lock)
+WAIP
<mode>
0
+CMGF
<mode>
1 (text)
+CSDH
X
0
+CNMI
All
0, 0, 0
+CSMP
All
1, 67, 0, 0
+CSCA
<sca>
SIM dependant (phase 2)
+CCWA
<n>
0
+CLIR
<n>
0
+CLIP
<n>
0
+COLP
<n>
0
+CBST
All
0, 0, 1
+CRLP
All
61, 61, 48, 6
+CR
<mode>
0
+CRC
<mode>
0
+IPR
X
0 (autobaud)
+IFC
X
2,2
+ICF
X
3,4
E
X
0
&C
X
1
&D
X
1
Q
X
0
V
X
1
&S
X
1
The default setting of the RS232 serial link handler shown above in
the table corresponds to the following setting:
Baud rate
: Autobauding (admitting rates from 2400 to
19200 bps)
Data length
: 8 bits
Parity
: None
Stop bit
: 1
Flow control
: Hardware (RTS/CTS)
To tune this settings please use the coIPR, +IFC and