WM_MKT_Fastrack_UGD_001 - 002
September 2002
As shown in Figure 2, the power supply cable is a tin copper wire with a:
•
core of 24 mm x 0.2 mm
•
cross-section of 0.75 mm
2
Figure 2: Diagram of power supply cable
2.2.1
Power Consumption
Following table provides information on power consumption of the Fastrack modem, assuming an
operating temperature of +25 °C.
Table 5: Power Consumption
EGSM 900
GSM 1800/1900
Min Typ Max Min Typ Max
Unit
@
5V
1.74 1.08
A
@
13.2V 0.73 0.41
A
Input Peak Supply Current
@32V
0.36 0.22
A
@
5V
330
218
mA
@
13.2V
130
94
mA
Input average supply current –
communication mode
@32V 65 50
mA
@
5V
31.4 31.4
mA
@
13.2V 13.2 13.2
mA
Input average supply current –
idle mode
@32V
5.6
5.6
mA
@
5V
8.8
8.8
mA
@
13.2V
4.1
4.1
mA
Input average supply current –
idle mode with RS232 autoshutdown*
@32V
2.2
2.2
mA
@
5V
5.1
5.1
mA
@
13.2V
2.5
2.5
mA
Input average supply current –
idle mode with full autoshutdown**
@32V
1.5
1.5
mA
* RS232 driver (MAX3238) automatically shuts down after 30s of inactivity on the serial link.
** RS232 driver in auto-shutdown and AT command
The power consumption might vary by 5% over the whole operating temperature range (-20°C to
+55°C)
The tests are carried out with a 3V SIM card.
confidential ©
Page :
9 / 29
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged without prior written
agreement.
Ce document est la propriété exclusive de WAVECOM. Il ne peut être communiqué ou divulgué à des tiers sans son
autorisation préalable.