Table 18: Interpretation of extended error codes 

Error 
Code 

Diagnostic 

Hint 

Phone failure 

Call technical support 

Operation not allowed 

Operation not supported 

No action 

10 

SIM not inserted 
 

Do one of the following: 
Insert the SIM card in the SIM holder of the 
modem 
Check that the SIM card is clean and properly 
inserted into the holder 

11 

SIM PIN required 

Enter PIN code 

12 

SIM PUK required 

Enter PUK code 
Note: Call your network provider if you do not 
know this code. 

13 

SIM failure 

Check validity of your SIM card. If SIM damaged, 
call your network provider 

16 

Incorrect password 

Check the code you entered 

17 

SIM PIN2 required 

Enter PIN2 code 

18 

SIM PUK2 required 

Enter PUK2 code  
Note: Call your network provider if you do not        
know this code. 

26 

Dialing string too long 

Check the phone number (max. 20 digits) 

30 

No network service 

No action 

32 

Network not allowed – emergency 
calls only 

No action 

40 

Network personalization PIN 
required (Network lock) 

Enter the Network lock 
Note : Call your network provider if you do not 
know this code. 

103 

Illegal MS (#3) 

No action 

106 

Illegal ME (#6) 

No action 

107 

GPRS services not allowed (#7) 

Contact your network provider to subscribe to the 
GPRS service 

111 

PLMN not allowed (#11) 

No action 

112 

Location area not allowed (#12) 

No action 

113 

Roaming not allowed in this location 
area (#13) 

No action 

132 

service option not supported (#32) 

Check the service option 

133 

requested service option not 
subscribed (#33) 

Call your network provider to subscribe to the 
requested service option 

134 

service option temporarily out of 
order (#34) 

No action 

149 

PDP authentication failure 

Call your network provider to know the right 
authentication parameters 

150 

invalid mobile class 

Change the class of the mobile to a valid one 

148 

unspecified GPRS error 

No action 

 

confidential ©

 

Page : 

23 / 29

This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged without prior written 
agreement.  
Ce document est la propriété exclusive de WAVECOM. Il ne peut être communiqué ou divulgué à des tiers sans son 
autorisation préalable. 

 

Summary of Contents for Fastrack M1200 series

Page 1: ...tember 2002 confidential Page 1 29 This document is the sole and exclusive property of WAVECOM Not to be distributed or divulged without prior written agreement Ce document est la propri t exclusive d...

Page 2: ...Creation 002 Sept 02 Complete Revision confidential Page 2 29 This document is the sole and exclusive property of WAVECOM Not to be distributed or divulged without prior written agreement Ce document...

Page 3: ...S A in France or in other countries All other company and or product names mentioned may be trademarks or registered trademarks of their respective owners WAVECOM S A may at any time and without notic...

Page 4: ...5 Getting started with Fastrack 16 5 1 Mounting Fastrack 16 5 2 Installing Fastrack modem 17 5 3 Verifying signal strength 17 5 4 Verifying network registration of the modem 18 6 Troubleshooting faile...

Page 5: ...ence documents 29 10 2 ETSI contact 29 10 3 Service 29 10 4 Disclaimer 29 10 5 Trademarks 29 10 6 Copyright 29 confidential Page 5 29 This document is the sole and exclusive property of WAVECOM Not to...

Page 6: ...Fastrack configuration 15 Table 14 Solutions for no carrier message 19 Table 15 Interpretation of extended error codes 20 Table 16 Solutions for no connection through serial link 21 Table 17 Solution...

Page 7: ...supply cable 1 fuse 1 user guide 2 Product details 2 1 Physical characteristics The Fastrack modem is small and lightweight Following table contains information on the physical characteristics of the...

Page 8: ...le 3 Operating voltage Operating voltage range 5 to 32 V Ground 0V 0 V The following table describes the consequences of overvoltage and undervoltage with the Fastrack modem Table 4 Effects of power s...

Page 9: ...mA Input average supply current idle mode 32V 5 6 5 6 mA 5V 8 8 8 8 mA 13 2V 4 1 4 1 mA Input average supply current idle mode with RS232 autoshutdown 32V 2 2 2 2 mA 5V 5 1 5 1 mA 13 2V 2 5 2 5 mA In...

Page 10: ...Band Extended GSM900 MHz Class 4 2W and GSM 1800 1900 MHz Class 1 1W Interface Serial interface RS232 V 24 V 28 Autobauding function AT command set based on V 25ter and GSM07 05 07 07 SMS Mobile Origi...

Page 11: ...he following table for the connectors that exist for the Fastrack modem Table 8 Fastrack connectors Connector Function Refer to SMA RF antenna connector Figure 3 15 pins SUB D high density RS232 link...

Page 12: ...ata set ready 12 RTS 105 Request to send 11 CTS 106 Clear to send RS232 13 RI 125 Ring indicator 4 Microphone 5 Microphone 10 Speaker Audio 15 Speaker 14 Reset Reset 3 Reserved Not applicable 2 4 1 2...

Page 13: ...connects to the modem via the SMA connector Use an antenna with the characteristics listed in following table Table 12 External antenna characteristics Antenna frequency range dual band GSM 900 1800...

Page 14: ...900 1900 Antenna adaptor SMA FME adaptor from PROCOM Power adaptor Europe EGSTON N2 EFSW 12V 1A mounted with Micro fit connector from MOLEX confidential Page 14 29 This document is the sole and exclu...

Page 15: ...twork no synchronization attempt RING Receiving an incoming call ATA OK Answer the call Do not forget the at the end for voice calls OK Communication established CME ERROR 11 PIN code not entered with...

Page 16: ...1 2 Bind the modem to the equipment using the holding bridles Refer to the following diagram Figure 7 Fastrack mounting confidential Page 16 29 This document is the sole and exclusive property of WAV...

Page 17: ...ector on the modem side 7 Activate the power supply 8 Plug the power supply cable into the Fastrack modem Note Refer to Figure 1 for a general presentation of the Fastrack modem Refer to Figure 6 for...

Page 18: ...ion 0 1 Yes 0 5 Yes registered roaming Note If the modem is not registered perform the procedure for Verifying signal strength to determine the strength of the received signal confidential Page 18 29...

Page 19: ...elected bearer type is supported by the network Type AT CEER to view the extended error code Refer to Table 15 Ensure that the selected bearer type is supported by the called party Ensure that the sel...

Page 20: ...ailable 68 ACM equal or greater than ACMmax Credit of your pre paid SIM card expired 252 Call barring on outgoing calls 253 Call barring on incoming calls Not applicable 3 6 8 29 34 38 41 42 43 44 47...

Page 21: ...ly connected to the modem and PC sockets Connect the cable as shown in Figure 4 Verify reception and transmission Is the communication program properly configured Ensure the following settings for the...

Page 22: ...e selected bearer type is supported by the network Type AT CMEE to view the extended error code Note Refer to Table 18 Ensure that the selected bearer type is supported by the called party Ensure that...

Page 23: ...etwork personalization PIN required Network lock Enter the Network lock Note Call your network provider if you do not know this code 103 Illegal MS 3 No action 106 Illegal ME 6 No action 107 GPRS serv...

Page 24: ...ations and generally in such a way that a separation distance of at least 20 cm is normally maintained between the transmitter s antenna and the body of the user or nearby persons The Modem is not des...

Page 25: ...cautions and or markings for their product Licensed module must have an FCC ID label on the module itself That FCC ID label must be visible through a window on the final device or it must be visible w...

Page 26: ...earing aids and pacemakers Consult the manufacturers of the medical device to determine if it is adequately protected Operation of your GSM Modem close to other electronic equipment may also cause int...

Page 27: ...be treated with care The suggestions below will help you to enjoy this product for many years Do not expose the GSM Modem to any extreme environment where the temperature or humidity is high Do not at...

Page 28: ...and out of the reach of children Remember your Unlock and PIN codes Become familiar with and use the security features to block unauthorized use and theft confidential Page 28 29 This document is the...

Page 29: ...ce e mail secretariat etsi fr 10 3 Service The AT commands manual is available from your local modem supplier 10 4 Disclaimer Modem and GSM unit specifications and manuals are subject to change withou...

Reviews: