WM_MKT_Fastrack_UGD_001 - 002
September 2002
Figure 1: Fastrack presentation
To ensure proper operation of the Fastrack modem, the operating environment must be within a
specific temperature range as described in following table.
Table 2: Optimal operating and storage temperatures
Operating temperature range
-20°C to +55°C
Storage temperature range
-25°C to +70°C
2.2 Electrical characteristics
The Fastrack modem is permanently ON once you connect the power supply cable to a functional
power supply (see Figure 2). Correct operation of the Fastrack modem is optimum in the following
voltage range:
Table 3: Operating voltage
Operating voltage range:
5 to 32 V
Ground (0V)
0 V
The following table describes the consequences of overvoltage and undervoltage with the Fastrack
modem:
Table 4: Effects of power supply defect
If the voltage:
Then the:
falls below 5 V
(undervoltage)
communication is not guaranteed
continuously peaks above
32V (overvoltage)
modem is protected by the fuse
power supply disconnects the electronic components from overvoltage
transiently peaks above 32
V (overvoltage)
modem guarantees its own protection
confidential ©
Page :
8 / 29
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged without prior written
agreement.
Ce document est la propriété exclusive de WAVECOM. Il ne peut être communiqué ou divulgué à des tiers sans son
autorisation préalable.