Adjusting the Light Level

This feature is factory set at maximum, so that even the brightest light will not prevent the sensor 

from turning the load ON when it detects occupancy. If this feature is not needed, leave the light level 

at maximum, fully clockwise.
The light level must be adjusted when lights would normally be turned OFF because there is enough 

natural illumintation. Each RH-250 may have a different light level setting.

1.  Set all RH-250s to Mode 1 (Manual-ON) - except for the one that you’re adjusting. 
2.  Set the RH-250 you’re adjusting so that it is in Mode 2 (Automatic-ON).
3.  Reduce the time delay to 15 seconds.
4.  Adjust the Light Level trimpot to minimum (fully counter-clockwise) on the unit that you’re 

adjusting. Move out of the coverage area. Let the sensor time out so lights are OFF and then 

wait 30 seconds more. 

5.  Without casting a shadow on the sensor, enter the area. The lights should remain OFF. 

Adjust the Light Level trimpot clockwise in small increments. After each adjustment, wait 5-10 

seconds to see if the lights turn ON.

Continue this procedure until the lights turn ON. At this setting the light will not turn ON automatically 

with occupancy if the light level measured at this sensor is above the current natural illumination.

6.  Repeat the process (beginning with step 1) for each RH-250 in your multi-way configuration 

until the Light Level has been adjusted properly in all of them.

7.  When you have finished adjusting the Light Level of all the RH-250s, return them all to Mode 2.
8.  Reset the time delay to the desired setting in all units.

Warning: Do not overturn the Light Level adjustment trimpot!

TEST MODE

To test the detection coverage:

1.  Press and hold the ON/OFF button. After 10 seconds the lighted switch turns off. The load turns ON if it was not already ON. The sensor is 

now in a TEST mode that lasts 5 minutes. (You can end the TEST mode sooner by pressing the ON/OFF button for another 10 seconds).
During the TEST mode, the controlled load turns ON for 5 seconds each time the sensor that initiated the TEST mode detects occupancy.

2.  Move out of the coverage area or stand very still. The controlled load turns OFF after 5 seconds if no motion is detected.
3.  Move into the coverage area for the unit that initiated the TEST mode. The controlled load turns ON for 5 seconds each time the sensor 

detects motion. After 5 seconds expire without motion detection, the load turns OFF. The controlled load turns ON automatically with the 

next motion detection and stays ON for 5 seconds.

4.  Repeat as necessary to ensure that the desired coverage areas are within detection range.

You can do this test for each RH-250 in your multi-way configuration. So that you can determine the actual coverage area for each multi-way 

switch individually, only the RH-250 that is in TEST mode will control the load.

TROUBLESHOOTING

Lighted switch is OFF, no load response to ON/OFF button press:

•  Make certain that the circuit breaker is on and functioning.

Lighted switch is ON, no load response to ON/OFF button press:

•  Check the lamp and/or motor switch on  the fan mechanism.

Load will not turn OFF automatically:

•  Press ON/OFF button. If the controlled load turns OFF, go to next step.
•  The time delay can be set from 15 seconds to 30 minutes. Check the time delay setting for each RH-250 in your multi-way 

configuration. Ensure that all RH-250s have the same time delay setting. 

•  Ensure that there is no movement within the coverage area for all the sensors related to the load for the set time delay. Hot air 

currents and heat radiant devices can cause false detection. Make sure the sensor is at least 6 feet (2 meters) away from devices 

that are a significant heat source (e.g. heater, heater vent, high wattage light bulb).

Load will not turn ON automatically when the area is occupied and the sensors are in Mode 2 (lighted switch is ON):

•  Press ON/OFF button. If the load turns ON, check the Light Level setting. The light level can prevent the sensor from turning ON 

the load automatically.

•  Make sure the sensor lenses are not blocked and that you are within the coverage area of at least one sensor.
•  If the load does not turn ON when you press the ON/OFF button, check the light bulb and/or motor switch on the fan mechanism.

If load does not respond properly after following troubleshooting, turn OFF power to the circuit then check wire connections or call technical 

support.

COVER PLATES

Wattstopper RH wall switches fit behind industry standard decorator style switch cover plates.

723

,1'22586(21

/<

/RFN%DU

0RGH%XWWRQ

 $GMXVWPHQW

7ULPSRWV

6OLGHWKH

2Q2II

%XWWRQ

GRZQZDUG

7LPH'HOD\

0LQ

6H

F

 

PLQXWH V

PD

[

PL

Q

0RGH

/LJKW

/HYHO

 ±0DQXD O

 ±$XWR2 1

P

D[

P

LQ

P

D[

P

LQ

 0L

0L

Q

6H

F

Fig. 8:  Sensor Adjustment Controls

Summary of Contents for RH-250

Page 1: ...rolled load is OFF When the controlled load is ON the LED is OFF Operating Modes For multi way operation of two or more RH 250s we recommend that the Operating Mode be the same in all sensors related to the same load This makes it easier to understand the multi way control operation as well as trouble shooting There are two operating modes to select from MODE 1 Vacancy sensor Manual ON OFF Auto OF...

Page 2: ...ores to the length indicated by the Strip Gauge in Fig 3 approx 1 2 inch 4 Wire the sensor Twist the existing wires together with the wire leads on the RH 250 sensor s as indicated in either step 4a or 4b Cap wires securely using wire nuts a Wiring two RH 250s in a 3 way configuration Connect the green or non insulated copper GROUND wire from the circuit to the green terminal on each RH 250 Connec...

Page 3: ... 2 inch to expose the mode button and adjustment trimpots For multi way operation the Operating Mode and the Time Delay adjustments should be the same in all sensors related to the same load Setting up the Operating Mode Select the operating mode by pressing the Mode button The amber LED behind the switch button blinks to indicate the selected mode The blink pattern repeats three times One blink i...

Page 4: ...ted the TEST mode The controlled load turns ON for 5 seconds each time the sensor detects motion After 5 seconds expire without motion detection the load turns OFF The controlled load turns ON automatically with the next motion detection and stays ON for 5 seconds 4 Repeat as necessary to ensure that the desired coverage areas are within detection range You can do this test for each RH 250 in your...

Page 5: ...inte manuellement l activation automatique est réactivée lorsqu aucun mouvement n est détecté pendant 5 minutes Cela permet d éviter que la charge ne s active automatiquement après avoir été volontairement désactivée Temporisation La temporisation peut être sélectionnée par l utilisateur pendant la configuration Elle peut être réglée sur l une des valeurs fixes suivantes 15 secondes 5 minutes 15 m...

Page 6: ...lage au fil blanc du RH 250 auxiliaire Raccordez le fil d alimentation de la boîte de circuits SOUS TENSION au fil noir du RS 250 auxiliaire et au fil VA ET VIENT 1 Raccordez le fil VA ET VIENT 1 depuis le fil noir du RH 250 auxiliaire au fil noir du RH 250 maître Raccordez le fil d alimentation de la lampe CHARGE au fil rouge du RH 250 maître Scellez le fil rouge sur le RH 250 auxiliaire Connecte...

Page 7: ... d inoccupation marche arrêt manuels extinction automatique Deux clignotements indiquent le mode 2 fonctionnement détecteur de présence marche arrêt automatique avec commande manuelle et réinitialisation à la commande automatique après 5 minutes d inoccupation Pour changer le mode appuyez une fois sur le bouton Mode pour régler l appareil au mode 1 ou appuyez deux fois sur le bouton Mode pour régl...

Page 8: ...tecteur repère un mouvement Après 5 secondes passées sans détection la charge s éteint La charge contrôlée s active automatiquement lors de la prochaine détection et reste active pendant 5 secondes 4 Répétez les étapes autant de fois que nécessaire de sorte que le champ de détection soit conforme à la zone de couverture recherchée Vous pouvez effectuer ce test pour chaque RH 250 de votre configura...

Page 9: ...be presionar el botón de ENCENDIDO APAGADO para encender la carga Uno o varios RH 250s controlando una misma carga la mantendrán encendida hasta que ninguno de ellos detecte movimiento por un periodo de tiempo denominado Retardo de Apagado configurable desde 15 segundos hasta 30 minutos Existe un periodo de 30 segundos inmediatamente después de que la carga se ha apagado automáticamente durante el...

Page 10: ...le blanco del otro RH 250 denominado como auxiliar El término maestro es utilizado acá únicamente para designar el sensor que esta conectado directamente a la carga controlada Conecte el cable de LINEA o FASE del circuito al cable negro del RH 250 auxiliar y al cable VIAJERO 1 Conecte el cable VIAJERO 1 proveniente del cable negro del RH 250 auxiliar al cable negro del RH 250 maestro Conecte el ca...

Page 11: ...deará una ó dos veces según sea Modo 1 ó Modo 2 El LED repetirá el patrón seleccionado tres veces Después de eso la unidad estará programada para operar en el modo seleccionado Ajuste del Retardo de Apagado Gire la perilla izquierda en dirección contraria a las manecillas del reloj para reducir el tiempo que permanecerá encendida la carga después de la última detección de movimiento valor mínimo 1...

Page 12: ...zca inmóvil La carga controlada se apagará después de 5 segundos si el sensor no detecta movimiento 3 Movilícese dentro del área de cobertura La carga controlada se encenderá por 5 minutos cada vez que el sensor detecte movimiento Después de transcurridos 5 segundos de no detección la carga se apagará La carga se encenderá automáticamente con la próxima detección y se mantendrá encendida por otros...

Reviews: