background image

7

STEP 6

Blue 1/4" Tube Connection - Faucet 
Connection

Step A - 

 Locate the ¼" blue tube 

connected to the RO Faucet .   

Connect the open end to the  

¼" elbow fitting on the back 

of the RO Module behind the 

Post-Carbon Filter .  Make sure 

the tube is pushed in all the way 

to the tube stop .   

STEP 7

Black 1/4" Tube Connection - Inlet Water

Step A

 -   Locate the ¼" black tube from 

the parts bag and insert one 

end into the plastic Adapt-A-

Valve .  Make sure the tube is 

pushed in all the way to the  

tube stop .

Step B -

   Insert the other end of the  

¼" black tube into the elbow 

behind the sediment filter next 

to the “IN” label .

STEP 8 - Option 1

Tank Valve Installation - Metal Tank Option

Step 1.A -

  Teflon tape must be applied in 

a clockwise direction .  Wrap 

5 to 7 turns around the male 

pipe threads (MPT) on the 

stainless steel fitting on top of 

the tank .

Step 1.B - 

 Thread the plastic valve onto 

the tank fitting

NOTICE

DO NOT over-tighten or the valve  
could crack

STEP 8 - Option 2

Tank Valve Installation - Plastic Tank Option

Step 2.A - 

 Make sure the O-ring is locat-

ed at the bottom of the recess 

for the tank connection

Step 2.B - 

 Thread the plastic valve onto 

the tank fitting

NOTICE

DO NOT use teflon tape on plastic tank

DO NOT over-tighten or the valve could crack

STEP 9

White 1/4" Tube Connection - Storage Tank 

Step A- 

 Locate the ¼" white tube from 

the parts bag .  Plug one end 

into the RO Module at the open 

port of the ASO Valve marked 

“Tank”

Step B -

   Plug the other end of the ¼" 

white tube into the valve at the 

Storage Tank .

STEP 10

Reverse Osmosis Module Mounting

Step A -

   Determine the best location 

for the RO Module to be 

mounted to allow for future 

system maintenance .  The 

parts bag has 2 self-tapping 

screws .  Using an electric drill 

with a phillips-driver bit, screw 

them into the cabinet wall 

approximately 10

5

/

8

" apart and 

16" from the bottom of the 

cabinet .

STEP 11

Install the Filter Cartridges

Step A - 

 Identify each cartridge and the 

proper location on the system 

by matching teh colors and 

descriptions .

Step B -

   Insert each cartridge with a 

¼-turn in a counter-clockwise 

direction .  The cartridge is 

installed properly when the label 

is facing toward the front of  

the unit .  

FEED / COLD

1/4” BLACK

7-12 TURNS

O-RING

TO INSTALL

POST-CARBON

RO MEMBRANE

POST-CARBON RO MEMBRANE

PRE-CARBON

Summary of Contents for WQC4RO11-50

Page 1: ...t Technical Warranty Information Performance Data Sheet 13 14 Arsenic Fact Sheet 14 Service Record 15 Limited Warranty 16 System tested and certified by WQA against NSF ANSI Standard 58 for the reduct...

Page 2: ...s The second stage contains a five micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane Recommended change...

Page 3: ...local regulations during installation Contents of Reverse Osmosis RO System 1 Tank 1 RO Module with Filters 1 Parts Bag 1 Faucet Box 1 Manual If any of the items are missing please contact prior to i...

Page 4: ...01504 Automatic Shut Off Valve ASOV J FU AGLR C 3 68102443 Air Gap Long Reach Chrome Faucet Option K FNP3033CP US05 68102285 Non Air Gap Long Reach Chrome Faucet Option L F122051 68101496 50 GPD Flow...

Page 5: ...g it for a sprayer or soap dispenser see Step A NOTICE Porcelain sinks are extremely hard and can crack or chip easily Use extreme caution when drilling Watts accepts no responsi bility for damage res...

Page 6: ...l screwdriver to feed through the drain saddle into the drain pipe to aid with the alignment Using a Phillips screw driver tighten the drain saddle bolts evenly and securely on both sides NOTICE Do no...

Page 7: ...cat ed at the bottom of the recess for the tank connection Step 2 B Thread the plastic valve onto the tank fitting NOTICE DO NOT use teflon tape on plastic tank DO NOT over tighten or the valve could...

Page 8: ...you have an 11 inch or 13 inch product and replace in 12 mos Model Part Description WQCSC11 68108818 Sediment Filter 11 inch WQCSC13 68108819 Sediment Filter 13 inch WQCCC11 68108777 Pre Carbon Filter...

Page 9: ...nce complete DANGER IF BLEACH GETS IN EYES Hold eye open and rinse slowly and gently with water for 15 20 minutes Remove contact lenses if present after the first 5 minutes then continue rinsing eye C...

Page 10: ...frequently over the next 24 hours to ensure no leaks are present NOTICE If you have connected your RO system to a refrigerator ice maker make sure the ice maker is off do not allow water to flow to t...

Page 11: ...ntinues check incoming water 3 System is constantly running Crimps in tubing Check tubing and straighten or replace as necessary Clogged pre filters Replace prefilters Fouled Membrane Replace Membrane...

Page 12: ...taste from water Tank needs to be sanitized Sanitize your system Filters are Fouled Replace Filters Filters weren t removed prior to an ex tended period of non use Replace filters and Sanitize your s...

Page 13: ...MENT PARTS AND CHANGE INTERVAL Note Depending on incoming feed water conditions replacement time frame may vary Determine if you have an 11 inch or 13 inch product Model Part Description Replacement I...

Page 14: ...Sheet Performance Data Sheet cont This system has been tested according to NSF ANSI 58 for reduction of the substances listed below and to NSF ANSI 372 for lead free com pliance The concentration of...

Page 15: ...__________ Model Number WQCRO4 Serial Number ______________ Date of Install _________________ Installed by __________________ Date Changed Sediment Pre Filter 6 Months Carbon Pre Filter 6 Months Membr...

Page 16: ...d 100 pounds per square inch 6 Incoming water to the filter system cannot exceed 100 degrees F 38 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is...

Reviews: