background image

8

 Operation

Startup Instructions

Step A  -

   Turn on the water supply at both the cold water supply 

valve and Adapt-A-Valve . Check the system for leaks and 

tighten any fittings as necessary .   (Check frequently over 

the next 24 hours to ensure no leaks are present) .

NOTE:    If you have connected your RO system to a refrigerator 

/ ice maker, make sure the ice maker is off (do not al-

low water to flow to the ice maker) until flushing (Step 

D) is complete and the tank has been allowed to fill 

completely. Connection from the RO to the ice maker 

system should have an in-line valve installed before 

the ice maker so it can easily be closed to prevent 

water flowing to the ice maker during start up and peri-

odic maintenance. Your storage tank must be allowed 

to fill up fully in order for the ice maker system to  

work properly.

  

Step B -

   Open the RO faucet and leave it open until water begins to 

trickle out (this may take a few minutes and the water will 

come out slowly) .

Step C -

   Close the RO faucet allowing the storage tank to fill with 

water .  It may take 3 to 6 hours to fill the tank completely 

depending on the production capability of the membrane, 

local water temperature and water pressure . 

NOTE:   During the fill period you may hear water trickling 

which is a normal occurrence.

Step D - 

   After the storage tank has filled open the RO Faucet to 

flush the tank completely . You will know that the tank is 

empty when the flow rate from the RO faucet is down to a 

trickle .  Repeat this step two more times .  The fourth tank 

can be used for drinking . 

NOTE:    The flushing process should take about a day to  

complete. 

NOTE:   Flushing of the tank 3 times is only necessary during 

the initial startup and after replacing the membrane

 .

Maintenance

NOTICE

Your RO module is equipped with valved heads which will auto-

matically turn off the water supply to each filter when the filter 

is released, thus you do not need to turn off the incoming water 

supply at the Adapt-a-Valve. The RO faucet must be off when 

filters are replaced.

6 Month System Maintenance

Determine if you have an 11 inch or 13 inch product and replace 

in 6 mos. 

Model # 

Part # 

Description

WQCSC11

68108818

Sediment Filter (11 inch)

WQCSC13

68108819

Sediment Filter (13 inch)

WQCCC11

68108777

Pre-Carbon Filter (11 inch)

WQCCC13

68108779

Pre-Carbon Filter (13 inch)

Annual Maintenance

Determine if you have an 11 inch or 13 inch product and replace 

in 12 mos. 

Model # 

Part # 

Description

WQCSC11

68108818

Sediment Filter (11 inch)

WQCSC13

68108819

Sediment Filter (13 inch)

WQCCC11

68108777

Pre-Carbon Filter (11 inch)

WQCCC13

68108779

Pre-Carbon Filter (13 inch)

WQCGAC11

68108795

Post Carbon Filter (11 inch)

WQCGAC13

68108796

Post Carbon Filter (13 inch)

Tip: This is a good time to check the 

air pressure in your storage tank. For 

instructions please see page 9.
Step A - 

  Place a towel under the RO 

module to catch any excess 

water that may drip out from the 

filters during the changeover .

Step B -

   To remove a filter cartridge: Turn 

the cartridge ¼-turn to remove .

Step C -

   To install a filter cartridge: 

Remove the seal cap and insert the cartridge into the valve 

head with the label facing to the left (9 o’clock positon) and 

then rotate it ¼-turn .    

Step D - 

  If performing the annual maintenance, flush the first tank 

full after completing the annual maintenance .

This reverse osmosis system contains a replaceable component 

(the RO membrane) which is critical to the efficiency of the sys-

tem. Replacement of this reverse osmosis membrane should be 

with one of identical specifications as defined by Watts to assure 

the same efficiency and contaminant reduction performance.

RO Membrane Replacement

Determine if you have an 11 inch or 13 inch product and replace 

in 2-5 years.

Model # 

Part # 

Description

WQCM11-50

68108809

RO Membrane Filter  

(11 inch-50 GPD)

WQCM13-100

68108810

RO Membrane Filter  

(13 inch-100 GPD)

Membranes have a life expectancy between 2 and 5 years, de-

pending on the incoming water conditions and the amount the 

RO system is used. This reverse osmosis membrane is critical 

for effective reduction of total dissolved solids (TDS). The prod-

uct water should be tested periodically to verify that the system 

is performing satisfactorily. 
Normally, a membrane would be replaced during a semian-

nual or annual filter change. However, if at any time you notice 

a reduction in water production or an unpleasant taste in the 

reverse osmosis water, it could be time to replace the mem-

brane. Watts recommends replacing the membrane when TDS 

reduction falls below 75%.
Refer to Instructions above filter change instructions
Step A -  

 To change your membrane, follow the instructions for the 

Annual Maintenance (previous section) . The procedure to 

remove and change the membrane cartridge is the same 

as all the other filter cartridges on the RO module . 

Step B -   

Check over the next 24 hours to ensure no leaks are  

present .

PULL

TO

INSTALL

TO

REMOVE

Summary of Contents for WQC4RO11-50

Page 1: ...t Technical Warranty Information Performance Data Sheet 13 14 Arsenic Fact Sheet 14 Service Record 15 Limited Warranty 16 System tested and certified by WQA against NSF ANSI Standard 58 for the reduct...

Page 2: ...s The second stage contains a five micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane Recommended change...

Page 3: ...local regulations during installation Contents of Reverse Osmosis RO System 1 Tank 1 RO Module with Filters 1 Parts Bag 1 Faucet Box 1 Manual If any of the items are missing please contact prior to i...

Page 4: ...01504 Automatic Shut Off Valve ASOV J FU AGLR C 3 68102443 Air Gap Long Reach Chrome Faucet Option K FNP3033CP US05 68102285 Non Air Gap Long Reach Chrome Faucet Option L F122051 68101496 50 GPD Flow...

Page 5: ...g it for a sprayer or soap dispenser see Step A NOTICE Porcelain sinks are extremely hard and can crack or chip easily Use extreme caution when drilling Watts accepts no responsi bility for damage res...

Page 6: ...l screwdriver to feed through the drain saddle into the drain pipe to aid with the alignment Using a Phillips screw driver tighten the drain saddle bolts evenly and securely on both sides NOTICE Do no...

Page 7: ...cat ed at the bottom of the recess for the tank connection Step 2 B Thread the plastic valve onto the tank fitting NOTICE DO NOT use teflon tape on plastic tank DO NOT over tighten or the valve could...

Page 8: ...you have an 11 inch or 13 inch product and replace in 12 mos Model Part Description WQCSC11 68108818 Sediment Filter 11 inch WQCSC13 68108819 Sediment Filter 13 inch WQCCC11 68108777 Pre Carbon Filter...

Page 9: ...nce complete DANGER IF BLEACH GETS IN EYES Hold eye open and rinse slowly and gently with water for 15 20 minutes Remove contact lenses if present after the first 5 minutes then continue rinsing eye C...

Page 10: ...frequently over the next 24 hours to ensure no leaks are present NOTICE If you have connected your RO system to a refrigerator ice maker make sure the ice maker is off do not allow water to flow to t...

Page 11: ...ntinues check incoming water 3 System is constantly running Crimps in tubing Check tubing and straighten or replace as necessary Clogged pre filters Replace prefilters Fouled Membrane Replace Membrane...

Page 12: ...taste from water Tank needs to be sanitized Sanitize your system Filters are Fouled Replace Filters Filters weren t removed prior to an ex tended period of non use Replace filters and Sanitize your s...

Page 13: ...MENT PARTS AND CHANGE INTERVAL Note Depending on incoming feed water conditions replacement time frame may vary Determine if you have an 11 inch or 13 inch product Model Part Description Replacement I...

Page 14: ...Sheet Performance Data Sheet cont This system has been tested according to NSF ANSI 58 for reduction of the substances listed below and to NSF ANSI 372 for lead free com pliance The concentration of...

Page 15: ...__________ Model Number WQCRO4 Serial Number ______________ Date of Install _________________ Installed by __________________ Date Changed Sediment Pre Filter 6 Months Carbon Pre Filter 6 Months Membr...

Page 16: ...d 100 pounds per square inch 6 Incoming water to the filter system cannot exceed 100 degrees F 38 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is...

Reviews: