background image

4

Parts List

Item

Model #

Part #

Description

A

WQCSC11

68108818

Sediment Filter (11 inch)

A

WQCSC13

68108819

Sediment Filter (13 inch)

B

WQCCC11

68108777

Pre-Carbon Filter (11 inch)

B

WQCCC13

68108779

Pre-Carbon Filter (13 inch)

C

WQCM11-50

68108809

RO Membrane Filter (11 inch-50 GPD)

C

WQCM13-100

68108810

RO Membrane Filter (13 inch-100 GPD)

D

WQCGAC11

68108795

Post Carbon Filter (11 inch)

D

WQCGAC13

68108796

Post Carbon Filter (13 inch)

E

ROPRO4-W

68107367

Plastic Tank (Option)

F

FRO-132-W

68102431

Metal Tank (Option)

G

PPSV500822W

68106280

Tank Valve

H

WTMFAG-C

68109023

Air Gap WTM Chrome Faucet (Option)

I

F134003

68101504

Automatic Shut-Off Valve (ASOV)

J

FU-AGLR .C/3

68102443

Air Gap Long Reach Chrome Faucet (Option)

K

FNP3033CP-US05

68102285

Non-Air Gap Long Reach Chrome Faucet (Option)

L

F122051

68101496

50 GPD Flow Restrictor

L

F123001

68101499

100 GPD Flow Restrictor

M

F560080

68101841

Adapt-A-Valve Kit

N

WE-CU138B-Q

68108672

3

/

8

" QC Drain Saddle

O

SC500B14

68107689

¼" Compression Drain Saddle

COLD WATER
ANGLE-STOP

(SUPPLY)

ADAPT

-A-

VALVE

WTM

FAUCET
OPTION

BLACK - 1/4” TUBE

FEED / COLD

H

M

RED -  1/4”

 TUBE

BRINE

METAL TANK OPTION

F

G

BLUE - 1/4”

 TUBE -  F

AUCET

WHITE - 1/4” TUBE

TANK

1/4”

DRAIN

SADDLE

O

BLACK - 3/8”

 TUBE

DRAIN

PLASTIC TANK OPTION

E

3/8”

DRAIN

SADDLE

N

AIR-GAP

CHROME

FAUCET
OPTION

J

RO MODULE

RO MODULE (REAR)

A

B

C

D

NON-AIR-GAP

CHROME

FAUCET
OPTION

K

I

WQC4RO Diagram & Parts List

Faucet only included in WQC4RO13 models

Summary of Contents for WQC4RO11-50

Page 1: ...t Technical Warranty Information Performance Data Sheet 13 14 Arsenic Fact Sheet 14 Service Record 15 Limited Warranty 16 System tested and certified by WQA against NSF ANSI Standard 58 for the reduct...

Page 2: ...s The second stage contains a five micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane Recommended change...

Page 3: ...local regulations during installation Contents of Reverse Osmosis RO System 1 Tank 1 RO Module with Filters 1 Parts Bag 1 Faucet Box 1 Manual If any of the items are missing please contact prior to i...

Page 4: ...01504 Automatic Shut Off Valve ASOV J FU AGLR C 3 68102443 Air Gap Long Reach Chrome Faucet Option K FNP3033CP US05 68102285 Non Air Gap Long Reach Chrome Faucet Option L F122051 68101496 50 GPD Flow...

Page 5: ...g it for a sprayer or soap dispenser see Step A NOTICE Porcelain sinks are extremely hard and can crack or chip easily Use extreme caution when drilling Watts accepts no responsi bility for damage res...

Page 6: ...l screwdriver to feed through the drain saddle into the drain pipe to aid with the alignment Using a Phillips screw driver tighten the drain saddle bolts evenly and securely on both sides NOTICE Do no...

Page 7: ...cat ed at the bottom of the recess for the tank connection Step 2 B Thread the plastic valve onto the tank fitting NOTICE DO NOT use teflon tape on plastic tank DO NOT over tighten or the valve could...

Page 8: ...you have an 11 inch or 13 inch product and replace in 12 mos Model Part Description WQCSC11 68108818 Sediment Filter 11 inch WQCSC13 68108819 Sediment Filter 13 inch WQCCC11 68108777 Pre Carbon Filter...

Page 9: ...nce complete DANGER IF BLEACH GETS IN EYES Hold eye open and rinse slowly and gently with water for 15 20 minutes Remove contact lenses if present after the first 5 minutes then continue rinsing eye C...

Page 10: ...frequently over the next 24 hours to ensure no leaks are present NOTICE If you have connected your RO system to a refrigerator ice maker make sure the ice maker is off do not allow water to flow to t...

Page 11: ...ntinues check incoming water 3 System is constantly running Crimps in tubing Check tubing and straighten or replace as necessary Clogged pre filters Replace prefilters Fouled Membrane Replace Membrane...

Page 12: ...taste from water Tank needs to be sanitized Sanitize your system Filters are Fouled Replace Filters Filters weren t removed prior to an ex tended period of non use Replace filters and Sanitize your s...

Page 13: ...MENT PARTS AND CHANGE INTERVAL Note Depending on incoming feed water conditions replacement time frame may vary Determine if you have an 11 inch or 13 inch product Model Part Description Replacement I...

Page 14: ...Sheet Performance Data Sheet cont This system has been tested according to NSF ANSI 58 for reduction of the substances listed below and to NSF ANSI 372 for lead free com pliance The concentration of...

Page 15: ...__________ Model Number WQCRO4 Serial Number ______________ Date of Install _________________ Installed by __________________ Date Changed Sediment Pre Filter 6 Months Carbon Pre Filter 6 Months Membr...