12
Problem
Possible Causes
Solution
6 . Leak at Fitting
Damaged Tubing
Disconnect the tube (See Section “Using Quick-Connect
Fittings” at beginning of manual) then cut about 1" from
the tube or replace tube and then re-insert . Replace
tubing if necessary .
Damaged Fitting
Replace fitting
7 . Unpleasant taste from water
Tank needs to be sanitized
Sanitize your system
Filters are Fouled
Replace Filters
Filters weren’t removed prior to an ex-
tended period of non-use
Replace filters and Sanitize your system
8 . Leaking at faucet
Faulty o-rings on lower faucet assembly
Check o-rings . Lubricate o-rings or replace lower faucet
assembly if damaged .
9 . TDS Levels are high
Fouled Membrane
Replace RO Membrane
Damaged Automatic Shut-Off Valve
Replace the Automatic Shut-Off Valve