![background image](http://html1.mh-extra.com/html/watts/wqc4ro11-50/wqc4ro11-50_installation-operation-and-maintenance-manual_3883338005.webp)
5
For
3
/
8
" Configuration
For 1/2" Configuration
STEP 3
Adapt-A-Valve Installation
NOTICE
Water supply line to the system must be from the cold water
supply line only. Hot water will severely damage your system.
NOTICE
Do not use Teflon tape with the Angle Stop Valve
D
B
Line from
Cold Water
Supply
Faucet
Connection
Faucet Line
Cold
Water
Supply
C
B
A
Parts List for Angle-Stop Valve
(verify contents prior to installation)
Item
Description
A
Brass Adapter with black washer
B
Plastic Adapt-A-Valve & black collet
C
White Rubber Washer
D
Brass Adapter with no washer
Step A -
Turn off the cold water supply to the faucet by turning the
angle stop valve completely off .
Step B -
Open cold water sink faucet to relieve pressure .
Step C -
Choosing the configuration that fits your plumbing, attach
the Adapt-A-Valve as illustrated in the diagram above .
NOTICE
Make sure that the black collet is installed in to the 1/4" opening
on the Adapt-a-valve. Don’t forget to install the white compres-
sion washer with the
3
/
8
" configuration. Brass adapters do not
need to be tightened with a wrench, only finger tight.
STEP 1
Drill a Hole for the Reverse Osmosis Faucet
Note: Most sinks are predrilled with 11/2" or 11/4" diameter hole
that you can use for your Drinking Water faucet. (If you are
already using it for a sprayer or soap dispenser, see Step A).
NOTICE
Porcelain sinks are extremely hard and can crack or chip easily.
Use extreme caution when drilling. Watts accepts no responsi-
bility for damage resulting from the installation of faucet.
Step A –
Determine desired location for
the RO faucet on your sink and
place a piece of masking tape
on over where the hole is to be
drilled . Mark the center of the
hole on the tape .
Step B –
Using a variable speed drill set
on the slowest speed, drill a
1
⁄
8
"
pilot hole through both porcelain
and metal casing of sink at the marked center of the de-
sired location . Use lubricating oil or liquid soap to keep the
drill bit cool (If drill bit gets hot it may cause the porcelain to
crack or chip) .
Step C –
Using a 1¼" diamond-tip hole saw . Keep drill speed on
the slowest speed and use lubricating oil or liquid soap to
keep the hole saw cool during cutting .
Step D –
Make sure the surroundings of the sink are cooled before
mounting the faucet to the sink after drilling and remove all
sharp edges .
STEP 2
Mount the Reverse Osmosis Faucet
NOTICE
Refer to installation instructions found on faucet box.
If Installing an Air-Gap faucet, connect the tubes as follows:
• 1/4" Red Tube -
Brine - Airgap inlet on faucet
•
3
/
8
" Black Tube -
Drain connection on faucet
• 1/4" Blue Tube -
Permeate/Filtered Water connection on faucet
(A Reducer may be needed)
If installing a Non Air-Gap faucet, connect as follows:
• 1/4" Blue Tube -
Permeate/Filtered Water connection on faucet