background image

5

For 

3

/

8

" Configuration

For 1/2" Configuration

STEP 3

Adapt-A-Valve Installation

NOTICE

  

Water supply line to the system must be from the cold water 

supply line only. Hot water will severely damage your system.

NOTICE

 

 Do not use Teflon tape with the Angle Stop Valve

D

B

 

Line from

Cold Water 

Supply

Faucet

Connection

Faucet Line

Cold

Water

Supply

C

B

A

Parts List for Angle-Stop Valve 

(verify contents prior to installation)

Item

Description

A

Brass Adapter with black washer

B

Plastic Adapt-A-Valve & black collet

C

White Rubber Washer

D

Brass Adapter with no washer

Step A -

  Turn off the cold water supply to the faucet by turning the 

angle stop valve completely off .  

Step B -

  Open cold water sink faucet to relieve pressure . 

Step C -

  Choosing the configuration that fits your plumbing, attach 

the Adapt-A-Valve as illustrated in the diagram above .

NOTICE

 

Make sure that the black collet is installed in to the 1/4" opening 

on the Adapt-a-valve.  Don’t forget to install the white compres-

sion washer with the 

3

/

8

" configuration.  Brass adapters do not 

need to be tightened with a wrench, only finger tight.

STEP 1

Drill a Hole for the Reverse Osmosis Faucet

Note:  Most sinks are predrilled with 11/2" or 11/4" diameter hole 

that you can use for your Drinking Water faucet. (If you are 

already using it for a sprayer or soap dispenser, see Step A).

NOTICE

Porcelain sinks are extremely hard and can crack or chip easily. 
Use extreme caution when drilling. Watts accepts no responsi-

bility for damage resulting from the installation of faucet.
Step A –

  Determine desired location for  

the RO faucet on your sink and 

place a piece of masking tape 

on over where the hole is to be 

drilled . Mark the center of the 

hole on the tape .

Step B –

  Using a variable speed drill set 

on the slowest speed, drill a 

1

8

pilot hole through both porcelain 

and metal casing of sink at the marked center of the de-

sired location . Use lubricating oil or liquid soap to keep the 

drill bit cool (If drill bit gets hot it may cause the porcelain to 

crack or chip) .

Step C –

  Using a 1¼" diamond-tip hole saw .  Keep drill speed on 

the slowest speed and use lubricating oil or liquid soap to 

keep the hole saw cool during cutting .

Step D –

  Make sure the surroundings of the sink are cooled before 

mounting the faucet to the sink after drilling and remove all 

sharp edges .

STEP 2

Mount the Reverse Osmosis Faucet

NOTICE

Refer to installation instructions found on faucet box.

If Installing an Air-Gap faucet, connect the tubes as follows:
 •  1/4" Red Tube -  

Brine - Airgap inlet on faucet

 •   

3

/

8

" Black Tube -  

Drain connection on faucet 

 • 1/4" Blue Tube -  

  

Permeate/Filtered Water connection on faucet  

    (A Reducer may be needed)

If installing a Non Air-Gap faucet, connect as follows:
 •  1/4" Blue Tube -  

Permeate/Filtered Water connection on faucet

Summary of Contents for WQC4RO11-50

Page 1: ...t Technical Warranty Information Performance Data Sheet 13 14 Arsenic Fact Sheet 14 Service Record 15 Limited Warranty 16 System tested and certified by WQA against NSF ANSI Standard 58 for the reduct...

Page 2: ...s The second stage contains a five micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane Recommended change...

Page 3: ...local regulations during installation Contents of Reverse Osmosis RO System 1 Tank 1 RO Module with Filters 1 Parts Bag 1 Faucet Box 1 Manual If any of the items are missing please contact prior to i...

Page 4: ...01504 Automatic Shut Off Valve ASOV J FU AGLR C 3 68102443 Air Gap Long Reach Chrome Faucet Option K FNP3033CP US05 68102285 Non Air Gap Long Reach Chrome Faucet Option L F122051 68101496 50 GPD Flow...

Page 5: ...g it for a sprayer or soap dispenser see Step A NOTICE Porcelain sinks are extremely hard and can crack or chip easily Use extreme caution when drilling Watts accepts no responsi bility for damage res...

Page 6: ...l screwdriver to feed through the drain saddle into the drain pipe to aid with the alignment Using a Phillips screw driver tighten the drain saddle bolts evenly and securely on both sides NOTICE Do no...

Page 7: ...cat ed at the bottom of the recess for the tank connection Step 2 B Thread the plastic valve onto the tank fitting NOTICE DO NOT use teflon tape on plastic tank DO NOT over tighten or the valve could...

Page 8: ...you have an 11 inch or 13 inch product and replace in 12 mos Model Part Description WQCSC11 68108818 Sediment Filter 11 inch WQCSC13 68108819 Sediment Filter 13 inch WQCCC11 68108777 Pre Carbon Filter...

Page 9: ...nce complete DANGER IF BLEACH GETS IN EYES Hold eye open and rinse slowly and gently with water for 15 20 minutes Remove contact lenses if present after the first 5 minutes then continue rinsing eye C...

Page 10: ...frequently over the next 24 hours to ensure no leaks are present NOTICE If you have connected your RO system to a refrigerator ice maker make sure the ice maker is off do not allow water to flow to t...

Page 11: ...ntinues check incoming water 3 System is constantly running Crimps in tubing Check tubing and straighten or replace as necessary Clogged pre filters Replace prefilters Fouled Membrane Replace Membrane...

Page 12: ...taste from water Tank needs to be sanitized Sanitize your system Filters are Fouled Replace Filters Filters weren t removed prior to an ex tended period of non use Replace filters and Sanitize your s...

Page 13: ...MENT PARTS AND CHANGE INTERVAL Note Depending on incoming feed water conditions replacement time frame may vary Determine if you have an 11 inch or 13 inch product Model Part Description Replacement I...

Page 14: ...Sheet Performance Data Sheet cont This system has been tested according to NSF ANSI 58 for reduction of the substances listed below and to NSF ANSI 372 for lead free com pliance The concentration of...

Page 15: ...__________ Model Number WQCRO4 Serial Number ______________ Date of Install _________________ Installed by __________________ Date Changed Sediment Pre Filter 6 Months Carbon Pre Filter 6 Months Membr...

Page 16: ...d 100 pounds per square inch 6 Incoming water to the filter system cannot exceed 100 degrees F 38 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is...

Reviews: