background image

2 WIRE INTERCOM SYSTEM

USER MANUAL

DT-ENG-37MG/TD7-V1

ENGLISH

Please read this manual carefully before using the product, and keep it well.

Summary of Contents for DT37MG

Page 1: ...2 WIRE INTERCOM SYSTEM USER MANUAL DT ENG 37MG TD7 V1 ENGLISH Please read this manual carefully before using the product and keep it well ...

Page 2: ...te hands free with visitor Press to view the outdoor condition in standby mode Microphone Receive voice from the user Mounting hook Use to hang up the monitor Connection port Bus terminal Speaker Send out vioce from the visitor L1 L2 1 2 3 ON DIP 4 5 6 L1 L2 1 2 3 ON DIP 4 5 6 SW SW Ring GND NC L1 L2 Bus terminal SW SW Door bell call button connection port Ring GND Extra buzzer connection port NC ...

Page 3: ... for 90 seconds After finishing communication press TALK MON button again or touch icon to end the communication If nobody answers the phone the screen will be turned off automatically after 30 seconds 00 30 Front Door It will display the call source string 1 Use the screws to fix the Mounting Bracket on the mounting box fitting accesories includes a Bracket Two pieces of 4X25 screws are needed to...

Page 4: ...e if the system connect 2 wire camera via camera controller press the camera 1 2 3 4 to monitor the camera you want press icon to exit and enter main menu page 5 Intercom Function 1 Inner Broadcast If multi slave monitors are installed in the same apartment select Inner Broadcast all the other monitors will mandatory receive broadcast content at the same time whichever slave monitor doesn t need t...

Page 5: ...tor when the Guard Unit Monitor answers the call conversation with the guard person is started 6 Video Picture Memory 4 01 Jim Zhang 02 Calo Liu 03 Jacko Zhang 04 Philips Chen 05 Hebe Zhang 06 Tony Li Name List 4 Video Picture Playback Touch Playback icon on main menu the recorded videos pictures will be played on screen please note that touch icon to Start Pause the videos recorded Video Picture ...

Page 6: ...06 18 20 54 Smith 06 12 11 06 Vincent Yang 05 29 08 39 Allen Chen 05 27 21 43 Hebe Zhang 04 20 13 16 Ben Wu Call Record 01 05 06 23 15 22 Calo Liu 06 18 20 54 Smith 06 12 11 06 Vincent Yang 05 29 08 39 Allen Chen 05 27 21 43 Hebe Zhang 04 20 13 16 Ben Wu Note 1 Automatic limited number of records 2 Do not need to delete any a record Note When the system without SD card 1 118 pictures in inner memo...

Page 7: ...divert modes 1 Don t Transfer calls from outdoor station will not be diverted 2 If No Answer outdoor station calls indoor monitor firstly if nobody answer the call within 30 seconds the call will be diverted to the telephone number you set At this mode the monitor will shut off immediately when TPC GSM TPS divert sucessfully while it won t affect the communication between TPC GSM TPS and outdoor s...

Page 8: ...e staircase light the staircase light will be turned off automatically 11 Basic Setup Instructions Sounds Settings Touch icon on main menu page or on door camera switching mode page then select Sounds item to enter the sounds settings page You can set a variety of ring tones on this page touch icon to exit the setting and return main menu page Transfer Options Don t Transfer If No Answer Simutaneo...

Page 9: ...exit the setting and return main menu page Note You can set your own time you can also synchronize the system time Rename Monitor Time Settings Touch icon on main menu page or on door camera switching mode page then select More item to enter the Rename monitor time settings page You can set door station rename camera rename monitor time on this page touch icon to exit the setting and return main m...

Page 10: ... all the modifications will be performed immediately after the operation Touch the window of image to exit the adjust page Screen and Volume Adjustment The restore to default function allows the user to recover the settings to factory setting Note that the restore to default operation will not change the setting and datas Enter main menu page and touch icon then select About item or touch logo pos...

Page 11: ...ard AUTO System Verson 00 01 00 Display Driver 1 0 Front 1 0 UI 1 0 INSTALLER SETUP 123 _ A Monitor can be assigned as Guard Unit Monitor when the Guard Unit Monitor answers the call conversation with the guard person is started The code number of 8004 is used to set the monitor as a guard unit monitor and 8005 is used to cancel this function How to set the monitor as a Guard Monitor The system of...

Page 12: ...ng at the same time and just the master monitor can display the image while the slave monitors can not But the settings can be changed you can set the master monitor and all the slave monitors to panel on at the same time when receiving a call just input the code number of 8006 on each slave monitor The unlock time can be changed by yourself at any time it can be set from 1 to 99 seconds The code ...

Page 13: ...6 ON Code 18 1 2 3 4 5 6 ON Code 29 1 2 3 4 5 6 ON Code 8 1 2 3 4 5 6 ON Code 19 1 2 3 4 5 6 ON Code 30 1 2 3 4 5 6 ON Code 9 1 2 3 4 5 6 ON Code 20 1 2 3 4 5 6 ON Code 31 1 2 3 4 5 6 ON Code 10 1 2 3 4 5 6 ON Code 21 1 2 3 4 5 6 ON Code 32 1 2 3 4 5 6 ON Code 11 1 2 3 4 5 6 ON Code 22 Bit 6 line terminal setting Bit state Setting Bit state Setting 1 2 3 4 5 6 ON Monitor not at the end of the line...

Page 14: ...h soft cotton cloth please do not use the organic impregnant or chemical clean agent If necessary please use a little pure water or dilute soap water to clean the dust 3 Image distortion may occur if the video monitor is mounted too close to magnetic field e g Microwaves TV computer etc 4 Please keep away the monitor from wet high temperature dust caustic and oxidation gas in order to avoid any un...

Page 15: ... 14 Note ...

Page 16: ...The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved DT ENG 37MG TD7 V1 ...

Reviews: