background image

Part Number

Add-On/Retrofit Kit

Description

Add-on and Retrofit Sensor Connection Kits for BMS

88003050

BMS Sensor Connection Kit, for LF909-FS  

Sizes 2½" to 10"

Includes a sensor activation module with cable, power adapter, 

and ground wire. Use this kit to activate the integrated  

flood sensor and enable flood detection capabilities for  

the relief valve to work with a third-party BMS control box  

(not included).

88003051

BMS Sensor Retrofit  

Connection Kit, for LF909 Sizes 2½" to 3"

Includes a flood sensor, sensor activation module with 

cable, power adapter, O-ring, mounting bolts, and ground 

wire. Use this kit to add flood detection capabilities to the 

relief valve of an existing installation working with a third-

party BMS control box (not included).

88003054

BMS Sensor Retrofit  

Connection Kit, for LF909 Sizes 4" to 10"

Includes a flood sensor, sensor activation module with 

cable, power adapter, O-ring, mounting bolts, and ground 

wire. Use this kit to add flood detection capabilities to  

the relief valve of an existing installation working with a 

third-party BMS control box (not included).

Add-on and Retrofit Sensor Connection Kits for Cellular Communication

88003052

Cellular Sensor Connection Kit, for LF909-FS  

Sizes 2½" to 10"

Includes a sensor activation module with cable, Cellular 

Gateway with mounting kit, power adapter, and ground 

wire. Use this kit to activate the integrated flood sensor  

and enable flood detection capabilities and e-mail, text,  

and voice notifications.

88003053

Cellular Sensor Retrofit Connection Kit,  

for LF909 Sizes 2½" to 3"

Includes a flood sensor, sensor activation module with 

cable, power adapter, Cellular Gateway with mounting kit, 

O-ring, mounting bolts, and ground wire. Use this kit to add 

flood detection capabilities to the relief valve of an existing 

installation and enable e-mail, text, and voice notifications.

88003055

Cellular Sensor Retrofit Connection Kit,  

for LF909 Sizes 4" to 10"

Includes a flood sensor, sensor activation module with 

cable, power adapter, Cellular Gateway with mounting kit, 

O-ring, mounting bolts, and ground wire. Use this kit to add 

flood detection capabilities to the relief valve of an existing 

installation and enable e-mail, text, and voice notifications.

RP-IS-909-909RPDA-FS-1915468

Watts

®

 909/LF909-FS

Diseñado para el mantenimiento en línea 

Tecnología integrada para la detección de inundaciones 

al activarse con el kit de conexión del sensor

Manual de instalación, mantenimiento y reparación

Serie 909, LF909-FS, 909RPDA-FS

Ensambles de zona de presión reducida y ensambles  

de detectores de presión reducida

Tamaños: 2

1

2

 in a 10 in (6.35 cm a 25.4 cm)

ADVERTENCIA

!

Lea este manual ANTES de utilizar este equipo.
No leer y seguir toda la información de seguridad y uso 

puede provocar la muerte, lesiones personales graves, 

daños a la propiedad o al equipo.
Guarde este manual para futuras consultas.

PIENSE 

PRIMERO EN

LA SEGURIDAD

Se requiere inspección y mantenimiento periódicos:

  Este 

producto se debe probar periódicamente de conformidad con 

los reglamentos locales, y al menos una vez al año o más, 

según lo requieran las condiciones de servicio. Si se instala en 

un sistema de extinción de incendios, todas las verificaciones 

mecánicas, como alarmas y dispositivos de prevención de reflujo 

deben probarse e inspeccionarse de acuerdo con las normas 

NFPA 13 y/o NFPA 25. Todos los productos deben volver a 

probarse una vez que se haya realizado el mantenimiento. Las 

condiciones corrosivas del agua y/o los ajustes o reparaciones 

no autorizados podrían hacer que el producto sea ineficaz 

para el servicio previsto. La verificación y limpieza periódica de 

los componentes internos del producto ayudan a garantizar la 

máxima vida útil y el correcto funcionamiento del producto.

ADVERTENCIA

!

ADVERTENCIA

!

La instalación y el mantenimiento de los ensambles de reflujo deben 

ser realizados por un técnico calificado y autorizado. El no hacerlo 

puede resultar en un ensamble defectuoso.

Las reglamentos locales de construcción o plomería 
pueden requerir modificaciones a la información 
proporcionada.  Debe consultar los reglamentos locales 
de construcción y plomería antes de realizar la instalación.  
Si la información proporcionada aquí no coincide con 
los reglamentos locales de construcción o plomería, se 
deben seguir el reglamento local. Este producto debe ser 
instalado por un contratista con licencia de acuerdo con los 
reglamentos y las disposiciones locales.

ADVERTENCIA

!

La serie 909/LF909-FS está equipada con un sensor de inundación 

integrado que, cuando se activa, activa la notificación de posibles 

eventos de inundación por descargas excesivas de la válvula de 

alivio. Se requiere una conexión de sensor adicional para implementar 

la activación. Hay disponible un kit de conexión de sensor de 

retroadaptación para las instalaciones existentes. Consulte “Kits de 

conexión de sensores adicionales y de retroadaptación” en la 

página 8.

AVISO

Para 

Australia

 y 

Nueva Zelanda

, se deben instalar filtros de línea 

entre la válvula de cierre de aguas arriba y la entrada del dispositivo 

de prevención de reflujo.

Para conocer el procedimiento de prueba de campo, consulte las 

hojas de instalación de Watts

®

 IS-TK-DL, IS-TK-9A, IS-TK-99E, y 

IS-TK-99D en 

watts.com.

Para otros kits de reparación y piezas de repuesto, consulte la 

lista de precios de piezas de repuesto y kits de reparación de 

productos de prevención de reflujo PL-RP-BPD en 

watts.com.

Para obtener asistencia técnica, póngase en contacto con su 

representante local de Watts.

Summary of Contents for 909 Series

Page 1: ...on WARNING WARNING The installation and maintenance of backflow assemblies should be performed by a qualified licensed technician Failure to do so may result in a malfunctioning assembly Local building or plumbing codes may require modifications to the information provided You are required to consult the local building and plumbing codes prior to installa tion If the information provided here is n...

Page 2: ... and local codes and meet the required safety provisions An air gap below the relief port must be maintained so as to avoid flooding and submersion of the assembly which may lead to a cross connection Figure 1 shows the primary components of the Series 909 LF909 FS Pipelines should be thoroughly flushed to remove foreign material before installing the unit A strainer should be installed ahead of t...

Page 3: ...h Test cock No 2 No 3 and No 4 When valve is filled open the downstream shutoff slowly and fill the water supply system This is necessary to avoid water hammer or shock damage The installation of a Watts air gap with the drain line terminating above a floor drain handles any normal discharge or nuisance spit ting through the relief valve However floor drain size may need to be designed to prevent ...

Page 4: ...all pressure differentials Close high valve A and open test cock No 2 Close test cock No 4 Disconnect vent hose at test cock No 4 Open valves B and C bleeding to atmosphere Then closing valve B restores the system to a normal static condition Observe the pres sure differential gauge If there is a decrease in the indicated value check valve No 1 is reported as leaking Test No 4 Purpose To test oper...

Page 5: ...e retainers Sizes 21 2 3 turn the seat by one quarter to remove it One wire is drawn out clockwise the other counterclockwise 4 Lift the seat ring straight up to remove it 5 To replace the disc on sizes 21 2 4 remove the retaining nut For sizes 6 10 remove the Allen head socket screws Reverse this procedure to install the new disc For further details contact your tech ni cal sales representative D...

Page 6: ... assembly 5 Inspect the bottom plug and spring assembly During normal field service there is no need to remove this assembly other than inspection Unscrew the assembly with a large pipe wrench CAUTION The spring is retained on the bottom plug and is highly loaded NO attempt should be made in the field to disassemble the bottom plug and spring piston assembly For replacement a complete bottom plug ...

Page 7: ...m and or electri cally isolate the device with plastic pipe immediately upstream and down stream of the device B 6 Valve improperly reassembled B 6 If the valve is dis as sem bled during installation exercise caution when installing check springs in their proper location C Valve exhibits high pressure drop C 1 Fouled strainer C 1 Clean strainer element or replace C 2 Valve too small for flows enco...

Page 8: ...55 4122 0138 Watts com Part Number Add On Retrofit Kit Description Add on and Retrofit Sensor Connection Kits for BMS 88003050 BMS Sensor Connection Kit for LF909 FS Sizes 2 to 10 Includes a sensor activation module with cable power adapter and ground wire Use this kit to activate the integrated flood sensor and enable flood detection capabilities for the relief valve to work with a third party BM...

Page 9: ...DVERTENCIA La instalación y el mantenimiento de los ensambles de reflujo deben ser realizados por un técnico calificado y autorizado El no hacerlo puede resultar en un ensamble defectuoso Las reglamentos locales de construcción o plomería pueden requerir modificaciones a la información proporcionada Debe consultar los reglamentos locales de construcción y plomería antes de realizar la instalación ...

Page 10: ...ientos de instalación deben cumplir con todos los códigos estatales y locales y cumplir con las disposiciones de seguridad requeridas Debe mantenerse un espacio de aire debajo del puerto de alivio para evitar inundaciones e inmersiones del ensamble lo que puede provocar una conexión cruzada La Figura 1 muestra los componentes principales de la serie 909 LF909 FS Las tuberías deben lavarse a fondo ...

Page 11: ...es necesario para evitar golpes de ariete o daños por golpes La instalación de un accesorio de espacio de aire Watts con la línea de drenaje terminando sobre un desagüe en el piso maneja cualquier descarga normal o escupida molesta a través de la válvula de alivio Sin embargo es posible que sea necesario diseñar el tamaño del desagüe del suelo para evitar daños por agua causados por una condición ...

Page 12: ...e la válvula alta A y abra la válvula de prueba N º 2 Cierre la válvula de prueba N º 4 Desconecte la manguera de aireación en la válvula de prueba N º 4 Abra las válvulas B y C purgando al ambiente A continuación el cierre de la válvula B restaura el sistema a una condición estática normal Observe el manómetro diferencial de presión Si hay una disminución en el valor indicado la válvula de retenc...

Page 13: ... Un alambre se extrae en el sentido de las agujas del reloj el otro en sentido antihorario 4 Levante el anillo del asiento hacia arriba para retirarlo 5 Para reemplazar el disco en tamaños de 21 2 in a 4 in 6 35 cm a 10 16 cm retire la tuerca de retención Para tamaños de 6 in a 10 in 15 24 cm a 25 4 cm retire los tornillos Allen Siga este procedimiento en orden inverso para instalar el nuevo disco...

Page 14: ...sario retirar este ensamble más que para la inspección Desenrosque el ensamble con una llave para tubos grandes PRECAUCIÓN El resorte está retenido en el tapón inferior y está muy cargado NO se debe intentar en el campo desmontar el tapón inferior y el ensamble del pistón del resorte Para el reemplazo debe obtenerse de fábrica un ensamble del tapón inferior completo Para obtener más información pó...

Page 15: ...sistema de tuberías y o aísle eléctricamente el dispositivo con una tubería de plástico inmediatamente aguas arriba y aguas abajo del dispositivo B 6 Válvula reensamblada incorrectamente B 6 Si la válvula se desmonta durante la instalación tenga cuidado al instalar los resortes de retención en su ubicación correcta C La válvula muestra una caída de presión alta C 1 Filtro sucio C 1 Limpie el eleme...

Page 16: ... del sensor con cable adaptador de corriente y cable de tierra Use este kit para activar el sensor de inundación integrado y habilitar las capacidades de detección de inundaciones para que la válvula de alivio funcione con una caja de control BMS de terceros no incluida 88003051 Kit de conexión de retroadaptación del sensor BMS para tamaños LF909 de 2 in a 3 in 6 35 cm a 7 62 cm Incluye un sensor ...

Reviews: