9
Figure 8. OASIS Wifi Wiring
Figure 8.1. OASIS Wifi Connector
NOTE:
Wire only one Wifi to
to ‘JP4’.
Make sure the wires are connected
in the right order. Wires should be
connected black, white, green, red
from the top down.
WIFI CONNECTION
Left to Right Wiring
RED
GREEN
WHITE
BLACK
5.1.3
Install a Solar Sensor
(if
applicable)
If there is solar, wire the solar panel temperature sensor to the 10-
pin blue connector.
The solar sensor should be installed adjacent to the solar panel
so it will read the same temperature as the solar panels. Do not
install in the pipe.
1. Feed the sensor wire through the black low voltage wiring
knockout.
2. Strip 1/4” of insulation and separate the wires.
3. Connect Solar sensor wires to pins #3 and #4. (see Figure 5.
Sensor Connection).
5.2.1
Mount the OASIS WiFi
Mount the OASIS WiFi at least 6 feet off the ground and at least
8 feet from motors, such as pumps or blowers, and other electrical
equipment.
5.2.2
Wire the OASIS WIFI
Connect the OASIS Wifi to the ‘JP4’ RS-485 connector
(see Figure 10.4 Wiring Diagram).
1. Feed wire through the black low voltage wiring knockout.
2. Connect the Black, White, Green, and Red wires as shown
in (Figure 8).
5.2
Install OASIS WiFi (if applicable)
NOTE:
For complete OASIS Pool Control App instructions and
information, refer to the OASIS WiFi instruction manual.
5.1.2
Replacing Air Sensor
The Air Sensor comes pre-installed in the OASIS Controller.
To replace the Air Sensor;
1. Remove nut located on the air sensor probe, remove probe.
2. On the 10 pin sensor connector loosen the screws & remove
wires on pin #7 & #8.
3. Install new air sensor and reattach red wire to pin #7 and
black wire to pin #8.
Figure 7. Sensor Connection
Figure 6. Air Temp Sensor
AIR TEMP SENSOR
AIR TEMP
SENSOR
PROBE
SENSOR CONNECTION
AIR TEMP
SENSOR
RED # 7
BLACK # 8
5.1.4
Install Additional Low Voltage
Equipment (i.e., Heater
Connection)
If there is additional low voltage equipment installed, such as low
voltage heating.
1. Feed the sensor wire through the black low voltage wiring
knockout.
2. Strip 1/4” of insulation and separate the wires.
3. Connect sensor wires to pins #1 and #2.