background image

Vspeed Setting:

 this option is selectable if the system is setup  

  for variable speed pump. These are the speeds if the user  
  manually presses the button. Use the MENU/LEFT/RIGHT buttons  
  to navigate to the appropriate field, then use the UP/DOWN  
  buttons to change the value. In this screen, “Prime” is for the start  
  up speed of the pump from OFF stage. Set the Prime duration to  
  zero minutes if prime is not needed.

Party Mode:

 this is used to set up one button push that will turn  

  on multiple devices. In this screen use the UP/DOWN buttons to  
  select the pool mode, then press the MENU/RIGHT button to enter  
  the accessories selection menu. In the accessories selection menu  
  use the UP/DOWN buttons to navigate to an accessory then use   
  the MENU/RIGHT button to select or deselect the accessory. LEFT  
  button  will go back to the previous screen.

Date-Time:

 set up the date and time for the pool. With Date-Time 

  highlighted, press MENU/RIGHT to enter the Date-Time setting. In  
  this screen, pressing MENU/RIGHT will move and highlight fields   
  that the user can change; UP/DOWN to change the values and LEFT  
  to go back to the previous field or screen.

General Information:

 displays general information of the pool.   

  With General Information highlighted, press MENU/RIGHT to enter  
  the General Information menu. Use LEFT to go back to the  
  previous screen.

Degree F/C:

 Select to display the pool temperature in Celsius or  

  Fahrenheit. With Degree F/C highlighted, press MENU/RIGHT to  
  toggle the selection between Celsius or Fahrenheit.

Time Display:

 display pool time in am/pm or 24-hour mode.  

  With Time Display highlighted, press MENU/RIGHT to toggle the  
  selection between am/pm or 24-hour selection.

Heat Source:

 this option can only be changed if a Solar valve or  

  Heat Pump is selected in ‘Assign Output’, as shown below:

Then Heat Source can be configured for Gas, Solar, or Heat Pump 
depending on which devices are configured in ‘User Control’.

With Heat Source highlighted, press MENU/RIGHT to choose the heat 
source.

Languages:

 to select the language for the pool display.  

  With Languages highlighted, press MENU/RIGHT to select a  
  specific language. 

Reset Network:

 this option clears the OASIS Wifi setting.  

  With “Reset Network” highlighted, press MENU or RIGHT buttons  
  to select the choice, then press LEFT or HOME buttons to execute. 

 

• 

Timers:

 set up schedules to turn devices ON/OFF. The number    

  of functions shown in this screen is dependent on the number of  
  accessories that are used in the system. Highlight the “Timers”  
  selection and press the MENU/RIGHT button to enter the setting.   
  In this screen, use the UP/DOWN buttons to highlight the desired  
  function, then press the MENU/RIGHT button to enter. LEFT button  
  will go back to the previous screen. 
  There are four schedules for each function that the user can set,  
  MENU/RIGHT will move to the next field, LEFT will move to  
  previous field or previous screen, and UP/DOWN will change the   
  value of a highlighted field. 
  All schedules are defaulted to OFF and changed to ON if the  

 

  schedule duration is set to a non-zero time and with a date  
  selected. Any function that requires the main pump to turn on will  
  show the Speed setting for the pump in the schedule.

810-2110.0219

©2019 Waterway Plastics

2200 East Sturgis Road, Oxnard CA 93030  •  

Phone 805.981.0262

  •  Fax 805.981.9403

[email protected]  •  

www.waterwayplastics.com

Designed, 

Engineered & 

Manufactured 

in the USA.

User Control

Timers

Installer Setup

Summary of Contents for OASIS

Page 1: ...TRUCTION MANUAL POOL SPA CONTROL 2200 E Sturgis Road Oxnard CA 93030 Phone 805 981 0262 Fax 805 981 9403 waterway waterwayplastics com www waterwayplastics com Designed Engineered Manufactured in the...

Page 2: ...ld consult a physician before using a spa or hot tub and should limit spa water temperatures to 100 F 38 C Water temperature in excess of 38 C 100 F may be injurious to your health c Before entering a...

Page 3: ...ne radio or television within five 5 feet 1 52m of a spa or hot tub The use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas Water temperature in...

Page 4: ...Hardware Mounting Hardware Mounting bracket Mounting Bracket Mounting Bracket for remotely installing UI Mounting Bracket for remotely installing UI Cover plate for UI housing Cover plate for UI hous...

Page 5: ...nted The four 4 mounting holes are 3 15 16 10 cm apart center to center NOTE Make sure to mark out the four 4 holes as accurately as possible 4 Drill four 4 holes in the mounting surface 5 Press the f...

Page 6: ...ician may conveniently access it All high voltage wiring must be done by a licensed electrical contractor NOTE See Figure 10 4 OASIS Electrical Wiring Diagram on page 10 for specific wire locations an...

Page 7: ...a Light Booster Pump etc Connect only one device per relay For each device 1 Connect ground wire to ground bar 2 Connect line power to Line 1 and Line 2 3 Connect equipment power to Load 1 and Load 2...

Page 8: ...the filter before the heater 2 Install the O ring on the sensor and insert the sensor into the hole Wrap and tighten metal clamp around the pipe to secure sensor 5 1 Wire the Temperature Sensors Wire...

Page 9: ...e OASIS Wifi to the JP4 RS 485 connector see Figure 10 4 Wiring Diagram 1 Feed wire through the black low voltage wiring knockout 2 Connect the Black White Green and Red wires as shown in Figure 8 5 2...

Page 10: ...SOLAR J4 OPTION FILTER PUMP AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 GROUNDING BAR WATERWAY OASIS TOPSIDE PANEL BREAKER BOX GROUND NEUTRAL OASIS WI FI KIT BLOWER FILTER PUMP J1 INTAKE J2 RETURN SOLAR TEMP SENSO...

Page 11: ...ERWAY OASIS TOPSIDE PANEL BREAKER BOX GROUND NEUTRAL OASIS WI FI KIT Variable Speed Connector Filter Pump High Filter Pump Low BLOWER FILTER PUMP J2 RETURN SOLAR TEMP SENSOR AIR TEMP SENSOR WATER TEMP...

Page 12: ...roller for a Variable Speed pump it is important to select the correct pump WWVSP Power Defender 165 Power Defender 270 WWVSP2 Power Defender 300 Intel VSP Pentair IntelliFlo pumps Hayward VSP select...

Page 13: ...Port for Jandy Pro Series VS pump WATERWAY VSP CONNECTION TO POWER DEFENDER 165 PUMP WATERWAY VSP CONNECTION TO PUMP BLACK COM WHITE B GREEN A WATERWAY VSP CONNECTION TO POWER DEFENDER 270 PUMP Figure...

Page 14: ...display Pool Set Temp with the current pool set temp In SPA mode it will display Spa Set Temp with the current spa set temp After 5 seconds without any change to the set temperature the screen will re...

Page 15: ...option Move between items in the left column with UP and DOWN Use the MENU or RIGHT button to navigate between columns By default the right column shows Not Used To change this setting use MENU or RIG...

Page 16: ...RIGHT to toggle the selection between am pm or 24 hour selection Heat Source this option can only be changed if a Solar valve or Heat Pump is selected in Assign Output as shown below Then Heat Source...

Reviews: