NOTE:
Waterway does not assume responsibility for software changes by other pump
manufacturers.
5.3.3.3
*Installing Communication Port
for Pentair IntelliFlo
®
& Hayward EcoStar
®
- Be sure to turn off or disable all pump priming and timer schedules
before connecting the pump to Waterway OASIS.
* Other pump models with the same name may be connected in the same way.
5.4
Install Waterway Valve Actuators
(WVAs) (if applicable)
You may wire up to four WVAs on the OASIS. Two (2) WVAs are
included in optional PS2 and PSW2 Pool/Spa kits. Additional WVAs
may be required on a pool/spa configuration to control a water
feature or solar panel.
NOTE:
Read and follow complete installation instructions and
safety information in the Waterway Valve Actuator owner’s
manual (included in the WVA packaging).
1. Install intake WVA and return WVA on equipment lines
according to installation instructions in the owner’s manual.
2. Feed intake WVA wire through the black low voltage wiring knockout.
3. Connect Intake WVA to ‘J1 Intake’ as shown in Figure 10.4 above.
4. Feed return WVA wire through the black low voltage wiring knockout.
5. Connect Return WVA to ‘J2 Return’ as shown in Figure 10.4 above.
13
5.3.3.2
*Installing Communication Port
for Jandy Pro Series VS pump
WATERWAY VSP CONNECTION TO
POWER DEFENDER 165 PUMP
WATERWAY VSP
CONNECTION TO PUMP
•
BLACK - COM
•
WHITE - B
•
GREEN - A
WATERWAY VSP CONNECTION TO
POWER DEFENDER 270 PUMP
Figure 12. Jandy Pro Series VSP Connection to Pump
JANDY PRO SERIES VSP CONNECTION
JANDY VSP CONNECTION
LEFT TO RIGHT WIRING
•
BLACK - NUMBER 2
•
YELLOW - NUMBER 3
•
GREEN - NUMBER 4
Figure 13. Pentair IntelliFlo/Hayward EcoStar Connection to Pump
HAYWARD PUMP
SIDE CONNECTION
PENTAIR INTELLIFLO
®
& HAYWARD
ECOSTAR
®
VSP CONNECTION
PENTAIR & HAYWARD
CONNECTION
LEFT TO RIGHT
•
YELLOW - NUMBER 2
•
GREEN - NUMBER 3
WATERWAY VARIABLE SPEED CONNECTION TO OASIS
WATERWAY VSP
CONNECTION TO OASIS
•
GREEN - NUMBER 2
•
WHITE - NUMBER 3
•
BLACK - NUMBER 4
Figure 11
Figure 11.1
Figure 11.2
VSP CONNECTION
TO PUMP
LEFT TO RIGHT WIRING
•
GREEN - NUMBER 2
•
WHITE - NUMBER 3
•
BLACK - NUMBER 4
WATERWAY VSP2 CONNECTION TO
POWER DEFENDER 300 PUMP
Figure 11.3 Note: Switch 3 must be moved to UP position
before connection to Power Defender 300
WATERWAY VSP2 CONNECTION TO PUMP
•
BLACK - COM
•
GREEN - A
•
WHITE - B
DOWN
UP
NOTE:
All DIP switches should be in off position
NOTE:
For Jandy Pro Variable Speed pumps - Please
connect High Voltage from pump directly to the breaker.
NOTE:
For Pentair & Hayward Variable Speed pumps - Please
connect High Voltage from pump directly to the breaker.