background image

8

 

 

                                                                                                                                                   

                                                                                                                                         

Main Menu

 

                             

12

:

00

 

   

 

                                                                        

1. To enter Main Menu, press the 

Menu/Enter

 button.

 

(Time of Day will flash)

2. To set the 

Time of Day

, press the 

Set/Change

 button.

 

(First digit will flash)   

 

 

 

 

    Example 

(

12

:

00

 

To change digit value, press the 

Set/Change

 button.

 

To accept the digit value, press the 

Menu/Enter

 button.

 

Next digit will flash to begin setting.

  

Once the last digit display is accepted, all digits will flash.

3. To set 

A.M.

 or 

P.M

., press the 

Menu/Enter

 button. 

  

To change digit value, press the 

Set/Change

 button.      Example 

(  

 A 

 )

  

To accept the digit value, press the 

Menu/Enter

 button.

  

Once A.M. or P.M. is accepted, the next menu item will flash.

 4. a. To set the 

Number of Days between Backwash Cycles

 (A), press the 

Set/Change

 button.     

 

 

 

   Repeat instructions from step (2).   

 

    Example

 ( 

A - 06

 )

 

 

               1) Maximum value is 29.

 

 

 2) If value set to 0, Automatic Backwash will never occur.

  

 

 3) Default setting is 6 days for filters.          

-  Final Checkout -

1. Be certain that the bypass valve is in Service position and main valve is completely on.

2. Check electrical supply to be certain the cord is connected to an uninterrupted 115 volt outlet.

3. REGISTER YOUR PRODUCT at www.watersoftinc.com

4. Leave this manual with the homeowner.

Important Notice - The plumbing system, piping, pressure tank, hot water tanks, softeners, etc. that have 

been exposed to iron bearing water may need to be cleaned of the precipitated iron that has been collected 

in them or iron bleed thru may be a problem. We suggest all tanks be drained and flushed thoroughly.

- Programming The Control Valve -

1. Set time of day.

2. Set a.m. or p.m.

3. Set number of days between backwash. (This generally will be every 4 to 6 days.)

1. Set regeneration time if other than 12:00 a.m. is desired.

Programming the Control Valve

Warning:

 Close handle on bypass prior to selecting the backwash position. After backwash position has 

                   been established, slightly open valve on bypass to evacuate air from the media tank. Fully open 

                   bypass valve when all air is depleted. This procedure will prevent media form being uplifted into 

                   control valve.

2. Advance control valve to RAPID RINSE (cycle 3) position and allow water to run to drain for 3 to 4 min   

    utes.

3. Advance control valve to SERVICE (cycle 0) position.

Summary of Contents for Provectr Plus AF10AC-3

Page 1: ...Provectr Plus Installation Operation Manual...

Page 2: ...Assembly Page 17 Service Instructions Page 18 Troubleshooting Page 19 Error Codes Page 20 Warranty Information Page 21 FCC Compliance Statement http www chandlersystemsinc com files FCC_Compliance_St...

Page 3: ...wn through the mineral bed of the filter and out the service lines The collected precipitates must be regularly removed from the filter by reversing the flow of water through the filter running to dra...

Page 4: ...will notice an 8 foot meter cord and plug attached Note If household plumbing is galvanized and you intend to make an installation with copper or vice ver sa obtain dielectric unions to prevent dissi...

Page 5: ...ypass valve indicate proper direc tion of water flow Install inlet and outlet piping in direction of arrows It is recommended that a vacuum breaker be installed on the inlet plumbing 1 Position AP tan...

Page 6: ...soaked while preparing the installation and will pre vent the control valve from being plugged with floating material on initial backwash H Remove funnel and clean filter material from tank threads I...

Page 7: ...ou hear and feel the O Ring pop into place before inserting the clip 2 Install 1 2 I D drain line tubing not included from hose barb to an open drain A 4 gap between end of the drain line and the open...

Page 8: ...cal supply to be certain the cord is connected to an uninterrupted 115 volt outlet 3 REGISTER YOUR PRODUCT at www watersoftinc com 4 Leave this manual with the homeowner Important Notice The plumbing...

Page 9: ...eft off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then restarts at that point when t...

Page 10: ...th the Menu Enter button After the entire display flashes press the Menu Enter button to move to the next menu item 2 Regeneration Cycle Step Times Steps 1 2 3 4 Example 3 10 The next 4 displays set t...

Page 11: ...the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve d...

Page 12: ...ms in ORANGE with a set button can be changed For Filters Set Backwash Frequency This sets the amount of day between backwash cycles Change Time of Day Press SET to set time automatically based on dev...

Page 13: ...p Option 2 Touch any graph to enlarge and see details Enlarged graphs are able to be zoomed in by pinching with two fingers Enlarged graph shown below Regenerate Unit at Next Regen Time button This wi...

Page 14: ...Encoder 20001X124 1 3 Front Plate 20001X004 1 4 Encoder Wheel 20001X007 1 5 Main Gear 21001X120 1 6 Power Supply 20001X125 1 7 Back Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Motor 2...

Page 15: ...15 Valve Body Drive Assy 2 1 3 18 19 28 12 17 16 4 8 9 10 11 14 15 13 24 20A 20B 26 27 21 25 22 16 23 5 7 6 6 6 6A...

Page 16: ...5 1 12 10 24 X 1 Screw SST 20001X226 2 13 3 8 Push Lock Plug 20009X010 1 14 Injector Cap 20009X001 1 15 Injector Seal 20001X224 1 16 Injector Plug O Ring Assy 20001X217 1 17 Injector Screen 20001X222...

Page 17: ...its 20017X284 3 1 Female Straight Slip Set optional 20017X288 4 1 NPT Straight Set optional 20017X289 5 3 4 NPT Straight Set optional 20017X307 6 1 X 3 4 Brass Sweat Connector Set optional 20017X304 7...

Page 18: ...cover C To Replace Piston Assembly 1 Follow steps A1 A3 2 Disconnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer...

Page 19: ...als Replace motor if motor is unresponsive F To Replace Meter 1 Follow steps A1 A3 2 Unplug meter cable from front of circuit board 3 Unscrew meter assembly nut from valve body 4 Remove meter from val...

Page 20: ...wheel for debris 2 Cycle power Valve should either find home or go to a different error code If error 4 returns replace powerhead assembly Error 5 Motor overload This occurs when the motor current is...

Page 21: ...charges service charges delivery expenses property damage administrative fees or any costs incurred by the purchaser in removing or reinstalling the water treatment equipment The Warranty does not cov...

Page 22: ...22...

Page 23: ...23...

Page 24: ...24 710 Orange Street Ashland OH 44805 PH 419 289 1500 FAX 419 289 1515 www watersoftinc com 0922TV...

Reviews: