1. Regeneration Time ( r )

   

 

 

Example 

 

( r 12A )

 

- The time of day at which backwash may take place is designated by the letter

 “

r

”.

 

- Default regeneration time settings

 is 12a

 

- The first display digit indicates A.M. or P.M. To change the value, press the 

Set/Change

 button.

 

- Press 

Menu/Enter

 button to accept the value and move to the next digit.

 

- The second and third display digits indicate the hour at which the backwash will occur.

 

- Change the digits with the 

Set/Change

 button and accept with the 

Menu/Enter

 button.

 

- After the entire display flashes, press the 

Menu/Enter

 button to move to the next menu item.

2.

 

Regeneration Cycle Step Times (Steps 1, 2, 3, 4)

 

  

    

 

 

 

 

 

 

Example

 

( 3 - 10)

 

- The next 4 displays set the duration of time in minutes for each backwash cycle step.

 

- The step number which is currently modifiable is indicated on the far left of the display screen.

 

- The number of minutes allotted for the selected backwash step is displayed on the far right.

 

- Change the digit values using the 

Set/Change 

and 

Menu/Enter

 buttons as described above.

  

3. Bluetooth Enabled   

  

BE - 1 

 

(ON)

 

 

 

 

 

BE - 0 

(OFF)

4. Bluetooth Password

  

BBPP

 is displayed for one second, then password is displayed.

5. 

To Exit the Master Programming Mode, press the 

Menu/Enter 

button until time of day returns.

Note

: If no buttons are pressed for 60 seconds, the Master Programming Mode will be exited automatically.

Filters

                                            Default (Min)

Step 1

Backwash

10

Step 2

Rest

  5

Step 3

Rapid Rinse

10

Step 4

Not Used

  0

Summary of Contents for Provectr Plus AF10AC-3

Page 1: ...Provectr Plus Installation Operation Manual...

Page 2: ...Assembly Page 17 Service Instructions Page 18 Troubleshooting Page 19 Error Codes Page 20 Warranty Information Page 21 FCC Compliance Statement http www chandlersystemsinc com files FCC_Compliance_St...

Page 3: ...wn through the mineral bed of the filter and out the service lines The collected precipitates must be regularly removed from the filter by reversing the flow of water through the filter running to dra...

Page 4: ...will notice an 8 foot meter cord and plug attached Note If household plumbing is galvanized and you intend to make an installation with copper or vice ver sa obtain dielectric unions to prevent dissi...

Page 5: ...ypass valve indicate proper direc tion of water flow Install inlet and outlet piping in direction of arrows It is recommended that a vacuum breaker be installed on the inlet plumbing 1 Position AP tan...

Page 6: ...soaked while preparing the installation and will pre vent the control valve from being plugged with floating material on initial backwash H Remove funnel and clean filter material from tank threads I...

Page 7: ...ou hear and feel the O Ring pop into place before inserting the clip 2 Install 1 2 I D drain line tubing not included from hose barb to an open drain A 4 gap between end of the drain line and the open...

Page 8: ...cal supply to be certain the cord is connected to an uninterrupted 115 volt outlet 3 REGISTER YOUR PRODUCT at www watersoftinc com 4 Leave this manual with the homeowner Important Notice The plumbing...

Page 9: ...eft off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then restarts at that point when t...

Page 10: ...th the Menu Enter button After the entire display flashes press the Menu Enter button to move to the next menu item 2 Regeneration Cycle Step Times Steps 1 2 3 4 Example 3 10 The next 4 displays set t...

Page 11: ...the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve d...

Page 12: ...ms in ORANGE with a set button can be changed For Filters Set Backwash Frequency This sets the amount of day between backwash cycles Change Time of Day Press SET to set time automatically based on dev...

Page 13: ...p Option 2 Touch any graph to enlarge and see details Enlarged graphs are able to be zoomed in by pinching with two fingers Enlarged graph shown below Regenerate Unit at Next Regen Time button This wi...

Page 14: ...Encoder 20001X124 1 3 Front Plate 20001X004 1 4 Encoder Wheel 20001X007 1 5 Main Gear 21001X120 1 6 Power Supply 20001X125 1 7 Back Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Motor 2...

Page 15: ...15 Valve Body Drive Assy 2 1 3 18 19 28 12 17 16 4 8 9 10 11 14 15 13 24 20A 20B 26 27 21 25 22 16 23 5 7 6 6 6 6A...

Page 16: ...5 1 12 10 24 X 1 Screw SST 20001X226 2 13 3 8 Push Lock Plug 20009X010 1 14 Injector Cap 20009X001 1 15 Injector Seal 20001X224 1 16 Injector Plug O Ring Assy 20001X217 1 17 Injector Screen 20001X222...

Page 17: ...its 20017X284 3 1 Female Straight Slip Set optional 20017X288 4 1 NPT Straight Set optional 20017X289 5 3 4 NPT Straight Set optional 20017X307 6 1 X 3 4 Brass Sweat Connector Set optional 20017X304 7...

Page 18: ...cover C To Replace Piston Assembly 1 Follow steps A1 A3 2 Disconnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer...

Page 19: ...als Replace motor if motor is unresponsive F To Replace Meter 1 Follow steps A1 A3 2 Unplug meter cable from front of circuit board 3 Unscrew meter assembly nut from valve body 4 Remove meter from val...

Page 20: ...wheel for debris 2 Cycle power Valve should either find home or go to a different error code If error 4 returns replace powerhead assembly Error 5 Motor overload This occurs when the motor current is...

Page 21: ...charges service charges delivery expenses property damage administrative fees or any costs incurred by the purchaser in removing or reinstalling the water treatment equipment The Warranty does not cov...

Page 22: ...22...

Page 23: ...23...

Page 24: ...24 710 Orange Street Ashland OH 44805 PH 419 289 1500 FAX 419 289 1515 www watersoftinc com 0922TV...

Reviews: