Safety
Introduction
Product Overview
Installation
Operation
Troubleshooting
Maintenance
Understanding the Shuttle Valve Operation
1
2
3
4
The shuttle valve engages as the pressure in the
system rises. It prevents air from escaping during
CAFS operation. When the system shuts down and
pressure is no longer applied to the valve, the
shuttle returns to its resting position and bleeds off
any remaining air in the system to atmosphere.
Note:
The
illustrates the main air pressure
route described in the instructions.
1 The rising pressure in the system moves the
shuttle into the operating position.
2 When operation ends, the lack of air pressure
moves the shuttle into the resting position.
3 Air in the lines migrates to atmosphere through
the red tubing.
4 Air in the compressor migrates to atmosphere
through the green tubing.