background image

20

Waterlogic 4 Firewall Technical Manual - Issue A, October 2010

21

COLD WATER

Press the cold water button. Cold water will be dispensed immediately.

AMBIENT WATER

Press the ambient water button and water will be dispensed.

SPARKLING WATER

Press the sparkling water button. Sparkling water will be dispensed 

immediately.

HOT WATER

Press and hold the hot water and extra hot water buttons together 

for  3  seconds  (This  safety  feature  prevents  hot  water  from  being 

dispensed  accidentally,  especially  by  children).  Amber  lighting  will 

illuminate  the  dispensing  area  to  confirm  your  selection,  and  hot 

water will be dispensed following a 3 second pause.

EXTRA HOT WATER

Press  the  extra  hot  water  button  and  the  hot  water  icon  on 

the  display  panel  will  light  to  indicate  that  the  water  is  heating. 

Once  the  icon  turns  off,  the  water  is  at  the  correct  temperature 

and  extra  hot  water  can  be  dispensed  following  the  same  

method as Hot Water.

Operating Instructions

Maintenance and Servicing

6 MONTH SERVICE PROCEDuRE

This  procedure  should  only  be  carried  out  by  persons  trained  by  Waterlogic 

International or their approved distributors.

The following instructions cover models that can include Hot, Cold, Ambient and 

Sparkling water.

•  Every six months the filters and UV lamp must be changed. 

•   The Firewall quartz spiral must be removed, checked and cleaned every six

  months if needed.

•  A WL4 Firewall with a hot water option may require having any calcium build up

  inside the hot tank removed, depending on local water conditions.

•  No paperwork or cleaning records should ever be stored inside the WL4 Firewall.

1. 

Isolate the power to the WL4 Firewall by turning off the green and red switches 

at the rear of the WL4 Firewall and by removing the power cord.

2.

 To access the filters slide the locking lugs located adjacent to the water dispensing 

faucet inward, then slide the top cover forward and lift it upward and back onto its 

hinges. Hold the top cover open using the top cover support strut located on the 

left hand side panel.

3.

 The two Waterlogic twist filters are at the front left hand side protruding through 

the WL4 Firewall’s upper metal shelf. Grip the 1st filter on the left and twist it clock 

wise to release it. This action will also isolate the water supply. Please remember 

that all Waterlogic twist filters are left handed thread. Pull the filter body upward 

when it releases and take precautions not to allow the used filter to drip water inside 

the WL4 Firewall or you can use the filter tool available from Waterlogic loosen and 

tighten the filter.

4.

 Turn off the CO2 supply (if servicing a sparkling water WL4 Firewall and drain the 

WL4 Firewall through the drain valves located at the rear. Have an adequate size 

container to drain the tanks into. (5L of water)

5.

  Remove the top cover of the Firewall chamber and remove the UV lamp first and 

then release the water feed fittings to the quartz spiral. Remove the quartz spiral. 

Clean the spiral removing any lime scale that may have adhered to the quartz surface. 

It is important to clean the quartz to allow maximum UV purification to take place. 

6.

 To sanitise the cold tank introduce sanitisation fluid at the back of the machine 

Summary of Contents for WL4 Firewall

Page 1: ...WL4 Firewall Technical Manual...

Page 2: ...ance and Servicing 21 Sanitising or Descaling 22 Fault Finding 23 Advisory Icons 24 Malfunction Icons 25 Technical Specifications and Warranties 27 ROHS 29 BioCote 29 Main PCB Schematic Diagram Hot Co...

Page 3: ...remove a whole range of contaminants e g chlorine and pesticides It is important for the UV sterilization system to be supplied with clean water in order to achieve maximum efficiency There are many k...

Page 4: ...5 16 The entire internal water circuit and all the components which come in contact with water are food grade NSF WRAS approved WATER VALVES Dispensing of water to the customer is achieved by means of...

Page 5: ...UT SPARKLING WATER OUT AIR VENT SOLENOID VALVE 5 SOLENOID VALVE 4 PUMP CHECK VALVE FILTER DRYER COLD SENSOR CHECK VALVE CO2 In COLD SPARKLING TANK DRAIN VALVE DRAIN VALVE DRAIN VALVE HOT TANK COMPRESS...

Page 6: ...WATER IN COLD WATER OUT SPARKLING WATER OUT SOLENOID VALVE 5 SOLENOID VALVE 4 PUMP FILTER DRYER COLD SENSOR CHECK VALVE CHECK VALVE CO2 In COLD SPARKLING TANK DRAIN VALVE DRAIN VALVE COMPRESSOR CONDEN...

Page 7: ...nd caution when lifting Packing materials could present a trip hazard Keep them off the floor Take care not to allow the power lead to get wet If the lead gets wet it must not be used CO2 gas used for...

Page 8: ...base cabinet if required using the separate instructions found in the base cabinet box 2 Mount the WL4 Firewall on a firm flat surface so that it cannot topple or fall from a counter top Level the WL4...

Page 9: ...will start to heat and cool 10 The water temperature of the WL4 Firewall is factory set at 5 C for still and spar kling water and 87 C for hot water The temperature can be adjusted see page 34 PCB Pro...

Page 10: ...enerally ready for use If the sleeping cat symbol is illuminated the WL4 Firewall has entered sleep mode pushing any button will bring the WL4 Firewall out of sleep mode Sleep mode is an energy saving...

Page 11: ...cal water conditions No paperwork or cleaning records should ever be stored inside the WL4 Firewall 1 Isolate the power to the WL4 Firewall by turning off the green and red switches at the rear of the...

Page 12: ...sed on the AMETEK filter system fitted with in and out pipe fittings will be needed to mix the sanitizing solution Flush the solution into the machine from the rear bulkhead Sanitising the machine usi...

Page 13: ...water 3 The hot water is not hot and cold water is not cold Make sure the green heater compressor switch is turned on 4 There is hot water flow but cold water is not flowing This may be due to the co...

Page 14: ...nternal WL4 Firewall leak detection system that will trigger an alarm or it will trip the Waterlogic block located on the installation kit Should you see water leaking from the WL4 Firewall isolate th...

Page 15: ...usual life expectancy of your water dispenser It will not wear or wash out with use or cleaning What bacteria is BioCote effective against BioCote is effective against most common bacteria moulds and...

Page 16: ...CDS WLS DS SLS 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 9 HLS 20S1 DC 24V 20S2 DC 24V 20S3 DC 24V 20S5 DC 24V 20S6 DC 24V DC 24V 20S4 DC 24V AC 230V AC 230V AC 230V AC 230V BT PCB MC MFC H OV P POWER SOUR...

Page 17: ...3 4 5 1 2 3 4 5 6 LED PCB DISPLAY PCB BUTTON PCB SW1 SW2 SW3 SW4 1 2 3 4 5 1 2 3 4 5 Electrical Wiring Diagram 230V Hot and Cold Mark Description Mark Description 20S1 Solenoid valve for in water MC...

Page 18: ...ater power switch 20S6 Solenoid valve for sparkling water PS3 Safe power switch AD Adaptor 24V SLS Sparkling water level check BT PCB Ballast PCB TH2 Thermistor cold water CDS UV sensor TH3 Thermistor...

Page 19: ...on Tube 5 16 for hot water mm 54 PU 4064 Silicon Tube 5 16 for hot water Air Vent 460mm Wetted Parts List Hot Cold and Sparkling Wetted Parts List Hot Cold and Sparkling NO Part NO Part Description 1...

Page 20: ...L 4 Drip Tray sensor Holder 18 CU 0055 WL 4 Air Vent Clip 19 PU 4064 Silicon Tube 5 16 for hot water 20 PL 1354 WL4 Firewall hot water faucet 22 PL 1354 A WL4 Firewall hot water faucet Insert Pipe 23...

Page 21: ...ra hot Button Label in four option model 92 EN 6118 Button PCB 93 EN 6116 A WL 4 Display PCB for Firewall CDS 94 PL 1334 WL 4 PCB Cover 95 PL 1333 WL 4 Back panel Hinge A 3 96 PL 1332 WL 4 Back panel...

Page 22: ...ata LED Display TEMP Actual temperature and filter use hours READ Read PCB Data SET Setting PCB Data SEND Sending Data to Machine FILTER Filter Reset Service PCB RS232 Power Adaptor WL4 Service Pcb Ki...

Page 23: ...data Press the Down button to read whole PCB setting and press Up button o read back from the top setting Note At this stage the Service PCB can read the actual settings and cannot change these settin...

Page 24: ...r button and the screen will diaplay STORING The screen will then change to display STORE SUCCESS The new setting data is now stored in the Service PCB only and is not within the WL4 FIREWALL PCB as y...