26
Waterlogic 4 Firewall Technical Manual - Issue A, October 2010
27
Technical Specifications
and Warranties
the tank to defrost, and then flush the cold water system. Check the temperature
settings are correct. If the cold tank is not frozen then check the solenoid valve is
operating correctly and being turned on and off when you push the cold button.
5.
There is cold water flow but hot water is not flowing: This may be due to calcium
build up in the hot tank or the hot water outlet. De-scale the hot tank. Check the hot
water solenoid valve functions correctly and turns on and off when you hold the hot
and extra hot buttons together for 3 seconds.
6.
Low flow of cold water or hot water or both: Check the building water pressure
to the WL4 Firewall is 45 PSI. Check the filters are not partially blocked, that the
solenoid vales function correctly, hot tank calcium build up need to be de-scaled,
cold tank ice build up needs to be defrosted.
7.
No sparkling water: Ensure the CO2 bottle is full and turned on and set at 45 PSI.
Turning the gas pressure above 45 PSI can stop the production of sparkling water.
Check the pump Icon. If flashing turn the power to the WL4 Firewall off for 1 minute
and then back on to reset the carbonation pump. The pump will time out if it runs
for more than 5 minutes continuously.
8.
Bad or plastic taste: If the WL4 Firewall is new it may need flushing for a longer
period.
Water leaks: Most leaks will be detected by either the internal WL4 Firewall leak
detection system that will trigger an alarm, or it will trip the Waterlogic block located
on the installation kit. Should you see water leaking from the WL4 Firewall, isolate
the supply and start normal fault finding procedures.
No power: Check the building electrical supply to the WL4 Firewall is on and that
the power cord is plugged in. Ensure the red power switch at the rear of the WL4
Firewall is on. Test the WL4 Firewall fuse. Check that the top cover isolation switch
is being activated by the top cover being locked in place correctly. If all these points
are OK then start normal fault finding procedures.
All Icons flashing and audible alarm: An over heat fault has been detected please
switch the WL4 Firewall off immediately and start fault finding procedures.
SAFETY
Subject to the standard terms and conditions of sale (a copy of which has been
provided to you), neither Waterlogic International Limited (“Waterlogic”), nor any
affiliated companies shall be liable for any damage which could affect, directly or
indirectly, any person or property.
Please be aware that any warranties accompanying the sale of our products will be
invalidated by any of the following:
• Incorrect installation
• Incorrect use of the WL4 Firewall
• Unsuitable electrical and water supply
• Major short-coming of maintenance
• Technical interventions or alterations of an unauthorised nature
• Adoption and use of unapproved spare parts
• Engagement of untrained personnel
Waterlogic has a policy of constant and continual improvement and therefore re-
serves the right to change specifications without prior notice, other than in the case
of significant changes.