                                                                   Page 35 – Revision 6‐28‐2019 

24.

 

Reconnect the UV wiring connectors.   

 

 

25.

 

With the Red Compressor / Heater Switch off, plug the 

WL270

 

Water Treatment System

 back 

into the power source.  Ensure the power LED is illuminated on the front of the 

WL270 Water 

Treatment System

.  The unit should start to fill. 

 

           DANGER!

 

 

ELECTRICAL SHOCK HAZARD.  

Do not plug in unit unless qualified.  Only qualified personnel who have read and understand this 
entire manual should attempt to install or service this unit.  

 

26.

 

Verify the UV Lamp has a faint blue glow underneath the silicon fittings on top of the UV lamp to 
ensure it is working.  The UV Lamp is directly connected to the electronic float, meaning the lamp 
will only be turned on when the unit is filling. 

 

       CAUTION!  

NEVER LOOK DIRECTLY AT A WORKING UV LAMP, EYE DAMAGE WILL OCCUR. 

 

UV Lamp Sensor is temperature sensitive.  During extended periods of use, especially when filling 
or draining the unit when water is not being dispensed, UV Lamp Sensor can overheat, initiating a 
UV Fault.  If this occurs, turn off unit for 5 minutes and allow sensor to cool before resuming 
operation. 

 

27.

 

Replace the top cover. 

 

28.

 

Once the reservoir has re‐filled, verify that all of the sanitizer has been rinsed from the hot, cold 
and ambient faucets.  Continue dispensing water from the faucets until the water tests chlorine 
free.  Draining, refilling and dispensing more water from the unit may be necessary to ensure the 
water is chlorine free. 

 

29.

 

Turn on the Red Compressor / Heater Switch.  This will start the chilling and heating processes. 

Red Compressor/Heater Switch must be in the I=ON position. 

30.

 

Verify the compressor starts by feeling the head of the compressor for vibration.  The 
temperature in the cold tank should reach its target temperature within 45 minutes.  When the 
unit has reached target cold temperature, the compressor will cycle off.  The Hot Tank will take 
considerably less time to reach its target temperature of 83

° (

181

°

F). 

 

31.

 

After the cold and hot water temperatures have been reached, turn the Red Heater/Compressor 
Switch off. 
 

Red Heater and Compressor Power

 

Switch must be in the O=OFF position while 

the Hot Tank is empty.  Damage could occur within one minute and the 
overload (high limit) will require manual reset if heater is turned on with an 
empty Hot Tank.  

 

 

 

Summary of Contents for WL270

Page 1: ...items Waterlogic recommends you establish a minimum of weekly visits to the machine for cleaning of the drip tray drain Washing of the Internal Plastic Reservoir Lid and Float Materials Needed Persona...

Page 2: ...an unused sponge or paper towels 5 Rinse well with clean water 6 While avoiding touching the wetted surfaces of the reservoir with your hands reinstall the Reservoir into the WL270 Water Treatment Sy...

Page 3: ...sure to replace your filters whenever you notice a decline in the performance whether it is a drop in flow rate and or pressure or an unusual taste in the water 9 Flush thoroughly per filter manufact...

Page 4: ...concentrated sanitizer Use extreme care 18 Once the cold tank is filled when the water starts streaming into the glass under the faucet release the cold dispense button Depress and verify chlorinated...

Page 5: ...or 5 minutes and allow sensor to cool before resuming operation 27 Replace the top cover 28 Once the reservoir has re filled verify that all of the sanitizer has been rinsed from the hot cold and ambi...

Page 6: ...owing this precaution prevents exposing personnel and equipment drains catch basin etc to scalding hot water Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor Power Switch to disable...

Page 7: ...F 37 C or below 35 F 2 C Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration syst...

Page 8: ...servoir to fill 5 Fill the Cold Tank Hold a container under the dispensing faucet press and hold the cold dispensing button until a continuous flow of water is obtained Once a continuous flow is obtai...

Page 9: ...is important to allow proper airflow and heat exchange of refrigeration system 9 Level unit using the adjustable feet to level if necessary Never install on incline 10 Turn the Red Heater and Compres...

Reviews: