background image

 

WL270

 Manual 

                                                                   Page 36 – Revision 6‐28‐2019 

DRAINING INSTRUCTIONS 

 

Drain the 

WL270

 Water

 Treatment System

 for transportation. 

 

       WARNING!

  

STORE UNIT EMPTY.  ALWAYS SANITIZE BEFORE REUSE. 

The unit must be completely drained and sealed before storing to avoid stagnation and reduce 
microbial growth).  

 

 

Prior to draining the Hot Tank, turn off the Red Heater and Compressor Power 
Switch 

O = OFF

, and dispense 2 liters of hot water from the machine.  As hot water 

is dispensed from the faucet of the unit, colder water will be introduced into the 
Hot Tank.  Since the Red Power switch is turned off, the heater will not energize 
and heat the incoming tap water.  Following this precaution prevents exposing 
personnel and equipment (drains, catch basin, etc.) to scalding hot water. 

 

Disable Cold and Hot Tanks 

 

1.

 

Turn off the Red Heater and Compressor Power Switch to disable the heater and 
compressor. 
 

2.

 

Dispense 2 liters of water through the Hot Tank to cool the water temperature in 
the Hot Tank and avoid burns.        
 

WARNING!  

HOT WATER CAN BURN OR SCALD.

 

Hot water should be dispensed carefully into insulated container to avoid injury. 

 

 

Turn off Water Supply and Bleed Water Pressure 
 

3.

 

Isolate the unit from feed water by turning off the supply.  
 

4.

 

Dispense cold still water to relieve any pressure built up in the system. 

 

5.

 

Remove the water supply line from the hose adaptor. 

 

Drain the Cold Water Tank and Circuit 
 

6.

 

Remove Hose Adaptor. 
 

7.

 

Remove Drain Caps located on back of unit. 
 

8.

 

After unit drains, replace drain caps. 

 
 

 
 
 

 

Summary of Contents for WL270

Page 1: ...items Waterlogic recommends you establish a minimum of weekly visits to the machine for cleaning of the drip tray drain Washing of the Internal Plastic Reservoir Lid and Float Materials Needed Persona...

Page 2: ...an unused sponge or paper towels 5 Rinse well with clean water 6 While avoiding touching the wetted surfaces of the reservoir with your hands reinstall the Reservoir into the WL270 Water Treatment Sy...

Page 3: ...sure to replace your filters whenever you notice a decline in the performance whether it is a drop in flow rate and or pressure or an unusual taste in the water 9 Flush thoroughly per filter manufact...

Page 4: ...concentrated sanitizer Use extreme care 18 Once the cold tank is filled when the water starts streaming into the glass under the faucet release the cold dispense button Depress and verify chlorinated...

Page 5: ...or 5 minutes and allow sensor to cool before resuming operation 27 Replace the top cover 28 Once the reservoir has re filled verify that all of the sanitizer has been rinsed from the hot cold and ambi...

Page 6: ...owing this precaution prevents exposing personnel and equipment drains catch basin etc to scalding hot water Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor Power Switch to disable...

Page 7: ...F 37 C or below 35 F 2 C Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration syst...

Page 8: ...servoir to fill 5 Fill the Cold Tank Hold a container under the dispensing faucet press and hold the cold dispensing button until a continuous flow of water is obtained Once a continuous flow is obtai...

Page 9: ...is important to allow proper airflow and heat exchange of refrigeration system 9 Level unit using the adjustable feet to level if necessary Never install on incline 10 Turn the Red Heater and Compres...

Reviews: