                                                      Page 34 – Revision:  4-15-22 

 
Materials Needed:  

 

Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear  

 

Phillips Screwdriver   

 

Temperature Gauge 

 

Water Pitcher or Container to collect water from the faucet 

 

5-gallon container or drain basin 

 

Sanitizer - Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner 

 

1/4” Plastic Tubing and assorted 1/4” quick connect fittings 

 

Sanitizing Cartridge 

 

Food Coloring (optional) 

 

 

1.

 

Unpack the 

Waterlogic WL15 Water Dispenser

 and check exterior for damage. 

 

 

2.

 

Identify the ports on the back of the machine. All ports are 
clearly labeled. The top port of the drainage is not used, only 
the lower port is connected and will drain the hot tank. Make 
sure the power switches on the back are turned OFF 
(

O=OFF

). 

 

 

3.

 

Remove the top cover by removing the two screws holding the lid in place (

2

and sliding back and lifting from the unit. Remove the other screws shown to 
release the side panel (

4

), then slide it back and pull away from the unit

 

 

 

Summary of Contents for WL15

Page 1: ...chemical product Take all necessary precautions to prevent sanitizer from contacting eyes clothing and any other surfaces in could damage carpets CAUTION HOT CIRCUIT IS NOT SANITIZED Water in the hot...

Page 2: ...ect fittings Sanitizing Cartridge Food Coloring optional 1 Unpack the Waterlogic WL15 Water Dispenser and check exterior for damage 2 Identify the ports on the back of the machine All ports are clearl...

Page 3: ...ion between the UV lamp and the PCB 8 Turn on the Soda switch on the back panel of the unit I ON to engage the carbonator pump and begin filling the carbonator tank The carbonator pump should be easil...

Page 4: ...pensed Small black flakes in the water are normal and is the purpose of this flushing operation This is only loose carbon from the filters Fill the Hot Tank 2 Using the control panel dispense hot wate...

Page 5: ...he center of the drain port which will allow the lower cap to be turned 180 degrees and removed Have a bucket or pitcher ready to catch the water as it drains out of the port 4 Once the water has comp...

Page 6: ...he upper panel aside 2 With the upper panel removed locate the UV module The UV bulb is inserted from the top with the wires running out and to the PCB Locate the plastic connector closest to the bulb...

Page 7: ...E POWER SOURCE 2 Locate the hot tank Then locate the high limit overload thermostat on the tank From this perspective it will be difficult to see The photos below illustrate what to look for 3 Press t...

Page 8: ...loves and eye protection when using chemicals Refer to Material Safety Data Sheet for specific requirements of each chemical product Take all necessary precautions to prevent sanitizer from contacting...

Page 9: ...the draining procedure for instruction on how to do this 5 Allow descaling solution to remain in the Hot Tank for 15 20 minutes 6 Reconnect the tube from the faucet to the center port of the Hot Tank...

Reviews: