                                                      Page 37 – Revision:  4-15-22 

WL15 DRAINING PROCEDURES 

 
CAUTION!

 

 

STORE UNIT EMPTY. ALWAYS SANITIZE BEFORE REUSE. 

The unit must be completely drained and sealed before storing to avoid stagnation and 
reduce microbial growth

 

 

 

DANGER!

 

 

HOT WATER. 

The Waterlogic WL15 Water Dispenser produces Hot Water up to 87°C (188°F). Water 
above 52°C (125°F) can cause severe burns or scalding.  Hot water should be dispensed 
carefully into insulated container to avoid injury.

 

 

1.

 

To drain the tanks of the Waterlogic WL15 Water Dispenser, first start 
with draining the Hot Tank. Shut off the Hot Switch on the back of the 
machine and dispense Hot water until it is cool to the touch. 

 

 

2.

 

Now, shut off the water supply. 

 

 

3.

 

Locate the drain port on the back of the machine. Use a screwdriver to slightly 
loosen the screw at the center of the drain port, which will allow the lower cap to be 
turned 180 degrees and removed. 

Have a bucket or pitcher ready to catch the 

water as it drains out of the port.  

 

4.

 

Once the water has completely drained from the Hot tank, replace the drain port 
cap and secure by tightening the screw down over the cap lip. 

 

5.

 

Next, drain the sparkling water from the system. Place a pitcher or the like in the 
dispensing area to catch the water as it comes out. With the gas connected and the 
Soda switch turned on, begin dispensing Sparkling water until only gas is coming out 
of the spout. Promptly turn off the Soda switch and shut the gas off at the bottle.  
 

6.

 

Again, with a pitcher in the dispense area, connect the gas line to the Water Supply 
port and turn the bottle on. Dispense Cold water from the system until only gas 
comes out of the spout (

it will only be a few ounces of water). 

Shut the gas off and 

disconnect the line. Dispense Cold water one last time to break any pressure buildup 
in the line. 

Summary of Contents for WL15

Page 1: ...chemical product Take all necessary precautions to prevent sanitizer from contacting eyes clothing and any other surfaces in could damage carpets CAUTION HOT CIRCUIT IS NOT SANITIZED Water in the hot...

Page 2: ...ect fittings Sanitizing Cartridge Food Coloring optional 1 Unpack the Waterlogic WL15 Water Dispenser and check exterior for damage 2 Identify the ports on the back of the machine All ports are clearl...

Page 3: ...ion between the UV lamp and the PCB 8 Turn on the Soda switch on the back panel of the unit I ON to engage the carbonator pump and begin filling the carbonator tank The carbonator pump should be easil...

Page 4: ...pensed Small black flakes in the water are normal and is the purpose of this flushing operation This is only loose carbon from the filters Fill the Hot Tank 2 Using the control panel dispense hot wate...

Page 5: ...he center of the drain port which will allow the lower cap to be turned 180 degrees and removed Have a bucket or pitcher ready to catch the water as it drains out of the port 4 Once the water has comp...

Page 6: ...he upper panel aside 2 With the upper panel removed locate the UV module The UV bulb is inserted from the top with the wires running out and to the PCB Locate the plastic connector closest to the bulb...

Page 7: ...E POWER SOURCE 2 Locate the hot tank Then locate the high limit overload thermostat on the tank From this perspective it will be difficult to see The photos below illustrate what to look for 3 Press t...

Page 8: ...loves and eye protection when using chemicals Refer to Material Safety Data Sheet for specific requirements of each chemical product Take all necessary precautions to prevent sanitizer from contacting...

Page 9: ...the draining procedure for instruction on how to do this 5 Allow descaling solution to remain in the Hot Tank for 15 20 minutes 6 Reconnect the tube from the faucet to the center port of the Hot Tank...

Reviews: