WL15
Manual
Page 36 – Revision: 4-15-22
12. Reconnect the UV lamp.
Filter Flushing
13. Shut off the water supply. Using the filter clips, clip in pre-flushed WL filters and plumb
them into the water line in series, with the first filter connecting to the line from inlet
bulkhead and the last filter connecting to the line feeding the solenoids.
Remember
, the
correct order for the filters is FT-0053, FT-0063, FT-0035. 53 should get water first and
35 should get water last.
NOTE
: If filters are NOT pre-flushed, flushing will be covered in
the next step.
14. Turn the water supply back on.
1.
If the filters were not pre-flushed, flush them now by dispensing at least a gallon of
water using
ONLY
the cold dispense operation. Place something in the dispense area to
catch the water being dispensed. Small black flakes in the water are normal and is the
purpose of this flushing operation. This is only loose carbon from the filters.
Fill the Hot Tank
2.
Using the control panel, dispense hot water until water begins to dispense. It may take
up to two minutes before any water flows from the faucet, as the hot tank is being filled
with water.
3.
Once water begins flowing using the hot dispense function, turn the hot
switch on at the rear panel of the unit. (
I=ON
)
Now, the water in the hot
tank will begin heating.
Regenerate the Sparkling Circuit
4.
Allow about 20-30min for the compressor and gas system to chill the sparkling water.
Then test the dispense function of all types of water to make sure it is both heated and
chilled to the desired temperatures.
UV System Functionality Test
5.
Dim or shield the overhead lights and peer into the top of the UV module. The blue glow
indicates the lamp is lit. If it is not, check the wire connections to the PCB and the bulb
itself.