INSTALLATION PROCEDURES 

 

Safety and Installation Guidelines 

Ensure all Local, State, and Federal Laws and Codes including health and safety guidelines are met when 
installing 

Waterlogic

 Equipment.   Only qualified service technicians should attempt installation and 

service of 

Waterlogic

 Equipment.     

 

WARNING!

  

ELECTRICAL SHOCK HAZARD.  

Always unplug (isolate from power supply) to prevent 

electrical shock except where electrical tests are specified.   

 

       WARNING!

  

IMPROPER SUPPLY OR CONNECTION CAN RESULT IS RISK OF SHOCK. 

Connect to a 15 amp 120V 60Hz properly grounded outlet (GFI is recommended).  Ensure polarity is 
correct and always use a 3‐prong outlet.  Consult a qualified electrician if you have any questions.     

 

WARNING!

  

USE ONLY Waterlogic SUPPLIED POWER CORD (EL‐5001‐A).

  Locate system within 5 

feet of power supply.  Never use an extension cord or adapter.  Do not use a damaged power cord or 
plug.  Keep power cord out of heavy traffic areas and away from heat sources.  Do not, under any 
circumstances, remove ground prong or alter the power cord.  Never pull the power plug from the 
outlet with a wet hand or allow the plug to get wet.  Failure to use the supplied power cord will void 
UL Certification and Warranty.   

 

CAUTION!

  

INDOOR USE ONLY

.   

Never exposed to direct sunlight, heat sources, or ambient air 

temperature above 97°F (3°6C) or below 50°F (10°C).  Install indoors and keep unit away from 
excessive humidity.  Never expose to freezing temperatures.  Ensure there is adequate clearance 
around the unit to allow refrigeration system condenser to dissipate heat.  Warmer environments 
require more clearance around the unit.  Minimum clearance around all surfaces of the machine is 2‐
inches.  Installs where the ambient temperature exceeds 80°F require a minimum of 4‐inches 
clearance for proper heat dissipation and efficient operation.    

 

CAUTION!

  

USE A WATER PRESSURE REGULATOR. Waterlogic

 will not be responsible for injury or 

damage caused by excessive water pressure.  Operating pressure must be 40 psi to 60 psi.  Be aware 
any of potential pressure surges caused by building/municipal pumping stations.   

 

CAUTION!

  

USE UV STABILIZED SUPPLY LINES.  

Feed the unit with a potable ambient or cold‐water 

supply only.

  

Feed water over 105° F (40° C) can damage the treatment components.  Water block 

devices and external leak detectors are strongly recommended. Locate the unit as close to the water 
supply and the electrical connections as possible.   

 

       WARNING!

  

STORE UNIT EMPTY.  ALWAYS SANITIZE BEFORE USE. 

The unit must be completely drained and sealed before storing to avoid stagnation and reduce 
microbiological contamination (potential bacterial growth).  Sanitize before use to eliminate any 
potential microbiological contaminates

 

 

Pre‐installation and sanitization procedures as prescribed in this manual must be performed before 
installing the 

CUBE Water Treatment System

 
 

Summary of Contents for CUBE

Page 1: ...ypochlorite or Citric Acid Based Cleaner Plastic Tubing at least 4 feet in length and assorted quick connect fittings TDS Meter and Test Strips for measuring chlorine Optional 1 8 NPT Female Thread to...

Page 2: ...ts of each chemical product Take all necessary precautions to prevent sanitizer from contacting eyes clothing and any other surfaces in could damage carpets 3 Remove the two screws at the rear of the...

Page 3: ...cure with two screws holding Top Cover in place 14 Connect 40 60 psi regulated potable water supply to the water inlet bulkhead fitting located on the back of the Cube Water Treatment System Turn on w...

Page 4: ...h 10 liters of cold water and 4 liters of ambient water through the machine to dilute and remove the sanitizer from the cold circuit You can use chlorine test strips to evaluate the water 19 Once the...

Page 5: ...green heater compression switch is in the O OFF CAUTION NEVER TURN ON HEATER BEFORE FILLING HOT TANK Green Heater and Compressor Power Switch must be in the O OFF position while the hot tank is empty...

Page 6: ...an cause severe burns or scalding Hot water should be dispensed carefully into insulated container to avoid injury Disable Cold and Hot Tanks 1 Turn off the Green Power Heater and Compressor Switch to...

Page 7: ...e above 97 F 3 6C or below 50 F 10 C Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrig...

Page 8: ...le tubing to the Reducer and the Water Supply Waterlogic requires the use of a water pressure regulator Water feed pressure must be between 40 60 psi 2 Turn on the water supply and check all of the co...

Page 9: ...tes Once a continuous flow is obtained flush 5 liters of water by continuing to hold the hot button Hot Tank is now full 10 Prime the Cold Circuit Holding a container under the dispensing faucet Selec...

Page 10: ...kin and eyes against ultraviolet rays Never look directly at an operating UV light Always disconnect before removal 16 Move the Waterlogic CUBE Water Treatment System into its final operating position...

Reviews: